Behavioral Helpless Stress Response Experiment of Rats and Mice with Electrical Stimulator
Behavioral Helpless Stress Response Experiment of Rats and Mice with Electrical Stimulator
Can perform constant voltage and constant current stimulation,currentThe voltage value can be adjusted, and it is an auxiliary device for studying animal emergency behavior, such as learned helplessness experiments, electrical stimulation emergency experiments, conditional fear experiments, etc.
Equipment composition:
1 power output device and 1 stimulation box
Small animal electrical stimulator
Product User Manual:
Specifications:
1、Has power outage memory function
2、Stimulator display:Three digit dual display
3、Stimulus box size:310X210X200mmtransparent
4、Controller dimensions:275X200X150mm
5、Power supply: controller12V,Stimulating power supply220V
6Voltage output range:0.1~200V
7Current output range:1~1999mA
There is also an upgraded acousto-optic stimulation device, with the green button serving as the acousto-optic stimulation controller. Pressing the green button will activate the acousto-optic stimulation, and pressing it again for three seconds will deactivate it. Acoustic and electrical stimulation can be performed separately or simultaneously.
Notes:
1Connect the wires of the stimulator with power, plug the red plug into the red socket, and plug the black plug into the black socket
2The red wire plug of the stimulation box is installed tightly against the upper metal plate, and the black wire plug is installed tightly against the lower metal plate. The two black knobs are tightened, and it is important to note that the exposed metal of the red wire should not touch the metal next to the black wire, and the exposed metal of the black wire should not touch the metal next to the red wire to prevent short circuits.
3Pay attention to adjusting the current, switching back to voltage mode, and conducting electrical stimulation experiments
4The time can be adjusted in minutes and seconds. After adjusting the time, press the switch and the time does not jump. It should be a time setting error and the time needs to be reset. Long press the blue key to set the decimal point, which can be accurate to milliseconds.
Mode setting:
P--1:delaylateT1After timeStimulator continuously discharges stimulation
P--2:Continuous discharge stimulationT1After time,Power outage ends
P--3:delaylateT1timeAfterwards, continuous discharge stimulationT2timeEnd.
P--4:Continuous stimulationT1After time,delayT2Time, then continuously discharge stimulation
P--5:delayT1After time,Continuous discharge stimulationT2timeRepeat the cycle.
P--6:Continuous discharge stimulationT1time,intervalT2timeRepeat the cycle.
Example: For example, a customer needsCurrent and voltage:0.1A,36VSet discharge stimulationT1Time is10In seconds,intervalT2Time is5In seconds,automaticcyclestimulateThe setting method is as follows:
1Press the green button above the stimulator to manually adjust the current,to0.1APress the green button above the stimulator again and manually adjust the voltage to36V.
2Long press the settings button, then press the up and down buttons to adjust the mode toP-6Short press the settings button to adjustT1Time's up10Short press the settings button again to adjustT2Time's up5Short press the settings button again.
3Press the power button to cycle and stimulate the work.