Overview

The QX-R1000 series paper recorder integrates multiple functions such as collection, display, processing, recording, and alarm. It can collect, store, and analyze important data in various industrial processes, mainly used for measuring and recording various industrial signals such as temperature, pressure, flow rate, voltage, current, and liquid level

Product Details

QX-R1000seriesPaper recorder setCollect, display, process, record, and alertIntegrated with multiple functions, it can collect, store, and analyze important data from various industrial processes, mainlyApplied to the measurement and recording of various industrial signals such as temperature, pressure, flow rate, voltage, current, liquid level, etc.

The measurement signal type, decimal point position, display range, recording boundary, alarm value, hysteresis, system error correction, recording ruler, data printing interval, paper feed speed, printing depth and time parameters can be set through the keyboard, and the set parameters can be protected.

QX-R1000The paper recorder adopts thermal printing technology and is a new generation recorder that replaces traditional pen based paper recorders.

2、 Main performance and technical indicators

1Input channel:·single pointDouble point three, four, five, six, eight o'clock
·The type of measurement signal for each channel can be set by the user themselves

It can also be specified when placing an order.[Set by the manufacturer for the user]

2Channel isolation:·The input channels are isolated from each other without interference.

3Display function:·Fixed point or cyclic display of measured values

·Set parameter display[In the set state]

·Alarm prompt and indicator light

·time display[When all input signals are turned off]

4Record function:·Adopting imported fixed thermal head, no ink consumption, no pen position

Error, anti vibration

·In100mmWithin the scope, there are800A hot printing spot

·Trend and numerical recording of measured values

·Print the ruler scale and each channel mark while recording the curve

·every100mmPrint the scale value, current time, and paper feed speed once

5Real time time:·Set the current date and time using the keyboard

·Even if there is a power outage,It doesn't affect normal timing either

6Curve migration function:By setting the recording boundary, the trend recording curves of different channels can be separated.

7Scale transformation function: For voltage and current input signals, linear scaling of the input signal can be achieved by setting the display range for display and recording. The display range of thermocouple and thermistor signals is their measurement range.

8Input signal type and measurement range:

Various thermocouples, thermistors, standard voltage and current signals, set and selected by keyboard

b0d3c9af5b5fc444069be56d66cb60e8_201407031546424955.jpg
9Paper speed:Set the paper feed speed arbitrarily through the keyboard10 mm/hto9990mm/h.

10Alarm function:

·Provide six sets of relay contact outputs for users to use in any combination

·Each channel alarm can select upper limit, lower limit, difference upper limit, and difference lower limit

The alarm hysteresis of each channel can be set, and there is an indicator light to prompt when the relay is activated

Relay contact capacity:24VDC, 3A 220VAC, 3A

11Communication: can provideRS232CorRS485Communication interface orUSB port This is an extended function,Please specify when placing an order

12Analog output:Can provide two routes4 ~ 20 mAAnalog transmission output

This is an extended function,Please specify when placing an order

13Sampling period:0.6S

14Digital display and alarm accuracy:±0.2%FŸS

15Trend recording accuracy:±0.2%Two pieces

16Digital recording accuracy:±0.2%FŸS

17input impedance: greater than10MWNote: When measuring current, the input impedance is250W

18Power consumption: not greater than30W

19Normal working environment:Temperature range:050°CHumidity range:1085 % RŸH

20Power supply voltage:220 V; 50 Hz

21. External dimensions:144 ′ 144 ′ 200 mm

22. Hole size:138+1 ′ 138+1 mm