BYD 4 pressure transmitter intrinsic safety stabilized switch power supply

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

BYD4 pressure transmitter intrinsic safety type voltage regulator switch power supply $r $nBYD4 series mining intrinsic safety pressure transmitter uses pressure chip. Sensitive components are formed by diffusion or ion implantation processes to form resistors and connected to a Wheatstone bridge. When a DC power supply is added, a DC voltage signal output is generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output.

Product Details

BYD 4 pressure transmitter intrinsic safety stabilized switch power supply

By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output

1. Environmental temperature: 0 ℃ to+40 ℃;

2. Average relative humidity: not exceeding 95% (+25 ℃);

3 Atmospheric pressure: 86kPa~106kPa;

4. No vibration and impact situations;

In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;

6. Underground coal mines.

7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,

Rated input voltage: 127VAC,

Rated output voltage: 18VDC.

By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output.

Use of BYD 4 pressure transmitter associated equipment in coal mine underground

1. Environmental temperature: 0 ℃ to+40 ℃;

2. Average relative humidity: not exceeding 95% (+25 ℃);

3 Atmospheric pressure: 86kPa~106kPa;

4. No vibration and impact situations;

In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;

6. Underground coal mines.

7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,

Rated input voltage: 127VAC,

Rated output voltage: 18VDC.

By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output.

1. Environmental temperature: 0 ℃ to+40 ℃;

2. Average relative humidity: not exceeding 95% (+25 ℃);

3 Atmospheric pressure: 86kPa~106kPa;

4. No vibration and impact situations;

In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;

6. Underground coal mines.

7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,

Rated input voltage: 127VAC,

Rated output voltage: 18VDC.

BYD 4 pressure transmitter intrinsic safety stabilized switch power supply