- Phone
-
Address
No. 12 Wangcheng Avenue, Xigong District, Luoyang City
Luoyang Qiaoyang Mining Machinery Co., Ltd
No. 12 Wangcheng Avenue, Xigong District, Luoyang City
BYD 4 pressure transmitter intrinsic safety stabilized switch power supply
By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output
1. Environmental temperature: 0 ℃ to+40 ℃;
2. Average relative humidity: not exceeding 95% (+25 ℃);
3 Atmospheric pressure: 86kPa~106kPa;
4. No vibration and impact situations;
In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;
6. Underground coal mines.
7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,
Rated input voltage: 127VAC,
Rated output voltage: 18VDC.
By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output.
Use of BYD 4 pressure transmitter associated equipment in coal mine underground
1. Environmental temperature: 0 ℃ to+40 ℃;
2. Average relative humidity: not exceeding 95% (+25 ℃);
3 Atmospheric pressure: 86kPa~106kPa;
4. No vibration and impact situations;
In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;
6. Underground coal mines.
7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,
Rated input voltage: 127VAC,
Rated output voltage: 18VDC.
By using diffusion or ion implantation processes to form resistors and connecting them to a Wheatstone bridge with a DC power supply, a DC voltage signal output will be generated. After a secondary conversion circuit, achieve a two-wire 4-20mA output.
1. Environmental temperature: 0 ℃ to+40 ℃;
2. Average relative humidity: not exceeding 95% (+25 ℃);
3 Atmospheric pressure: 86kPa~106kPa;
4. No vibration and impact situations;
In coal mines where there is a mixture underground, but there is no corrosive gas that damages the insulation;
6. Underground coal mines.
7 Associated devices: MCDX-II-a/18 mining isolation and intrinsically safe voltage regulating switch power supply,
Rated input voltage: 127VAC,
Rated output voltage: 18VDC.
BYD 4 pressure transmitter intrinsic safety stabilized switch power supply