BLA-LGT-800 laser gas analyzer (disk mounted)

NegotiableUpdate on 11/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Introduction: BLA-LGT-800 Laser Gas Analyzer is a disk mounted tunable laser gas analyzer developed by the company for industrial online analysis and environmental monitoring at home and abroad. The core of the instrument uses a White cell to achieve optical path reversal, with an optical path length of up to 25m and a low detection limit

Product Details

  • Introduction

The BLA-LGT-800 laser gas analyzer is a disk mounted tunable laser gas analyzer developed by the company for industrial online analysis and environmental monitoring at home and abroad. The core of the instrument uses a White cell to achieve optical path reversal, with an optical path length of up to 25m and a low detection limit. Multiple gases including O2, CO, NH3, CO2, CH4, H2O, HCl, HF, HCN, etc. can be analyzed online under various complex working conditions (note: a single analyzer can only analyze 1-2 components), and the measured gas concentration ranges from constant to trace.


  • feature

19 inch 3U disk mounted chassis, compact structure, easy to integrate;

Using TDLAS technology, the interference of background gas crossing has been eliminated;

By using multiple reflection optical path technology, the maximum measured optical path length can reach 25m, significantly improving the detection limit level;

High reliability without optical moving parts, and on-site vibration has no impact on measurement.


  • application

Gas analysis of metallurgical steelmaking furnace; Petrochemical refining; Urea chlor alkali manufacturing process gas.


  • Specifications

Linear error: ≤± 1% F.S

Zero drift: ≤± 1% F.S./Half year

Range drift: ≤± 1% F.S./Half year

Calibration cycle: ≤ 2 times/year

Response time: ≤ 30s (depending on operating conditions)

Analog input: 2-channel 4-20mA input

Analog output: 2-channel 4-20mA output

Digital communication: RS485/RS232/GPRS

Working temperature: -20 ℃~+60 ℃

Purging gas: (0.3-0.8) MPa nitrogen, purified instrument air