Welcome Customer !

Membership

Help

Shanghai Huanao Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

BINDER MKT240 High and Low Temperature Alternating Climate Chamber

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
BINDER MKT240 High and Low Temperature Alternating Climate Chamber
Product Details

BINDER MKT240 High and Low Temperature Alternating Climate Chamber

1、 Product Introduction:

1. Temperature range: -70 ℃ to 180 ℃

2. Four zero voltage switch contacts that can be activated through the MCS controller

3、APT.lineTMPreheating chamber technology

4. Programmable condensation protection for samples

5. Heated observation window with LED internal lighting

6. BINDER communication software APT-COM 3 Basic version

7. Fault diagnosis system using optical and sound alarms

8. Controller using interval programming

9. Access hole with silicone plug 50mm, left

10. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm

11. 4 casters, 2 with brakes

12. Computer interface: Ethernet

13. 230 V socket on the right side operating component

14. Display through LCD color monitor

15. Adjustable slope function function function

16. Integrated continuous automatic recorder

17. Real time clock

18. Door heating

19. A bracket made of stainless steel

20. BINDER testing certificate

21. Inner chamber made of stainless steel

22. PT100 temperature sensor

23. Heat insulation through polyurethane foam

24. Fluorine free refrigerants R-404A and R-23

25. Cooling is achieved through a cascaded compression cooler

26. Finned evaporator

2、 Technical parameters:

Product Model

MKT240-400V1

MKT240-400V-C1
Choose a model standard Equipped with transformer and frequency converter
Item code 9020-0196 9020-0296
measurement
Internal volume [L] 228 228
Net weight of equipment (unloaded) [kg] 380 380
Maximum total load [kg] 70 70
Maximum load per partition [kg] 30 30
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 1115 1115
Net weight at height [mm] 1935 1940
Depth net weight [mm] 925 925
Wall to side distance [mm] 300 300
Wall distance from rear [mm] 230 230
Observation window width [mm] 508 508
Observation window height [mm] 300 300
internal dimensions
Width [mm] 735 735
Height [mm] 700 700
Depth [mm] 443 443
number of doors
outer gate 1 1
Data related to the environment
Sound pressure level [dB (A)] 64 67
firmware
Number of partitions (hours/maximum) 1/6 1/6
Temperature performance data
Temperature range [℃] -70…180 -70…180
The temperature deviation depends on the set value [± K] 0.1…1.0 0.1…1.0
The temperature fluctuation depends on the set value [± K] 0.1…0.4 0.1…0.4
The average heating rate is based on IEC 60068-3-5 [K/min] 5 5
Cooling time from 180 ℃ to -70 ℃ [min] 95 95
The average cooling rate is based on IEC 60068-3-5 [K/min] 4.2 4.2
The maximum thermal compensation is at 25 ℃ [W] 3000 3000
Electrical data
Rated voltage [V] 400 480
Power frequency [Hz] 50 60
Rated power [kW] 6.5 6.5
Equipment safety device [A] 16 16
Phase (rated voltage) 3~ 3~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.