Welcome Customer !

Membership

Help

Beijing Beijiameiyi Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Beijiameiyi Biotechnology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 1510, 15th Floor, Building 2, No. 106 Kexing West Road, Huilongguan Town, Changping District, Beijing

Contact Now

BD-FACSCanto flow cytometer

NegotiableUpdate on 06/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Our company provides a full range of BD flow cytometers for analysis and sorting. The BD-FACSCanto flow cytometer models include: FACSCalibur,FACSCanto I、II,FACSAria I、II、III,Accuri C6,Accuri C6 Plus Wait, 90% new, engineers come to install and debug instruments, one-year warranty.

Product Details

1BD-FACSCanto flow cytometerProduct features:

1. Total reflection optical path design with excellent detection performance

Detection sensitivity: FITC<100MESF, PE<50MESF

Faster detection speed: 10000 cells/s

Extremely low sample residue: ≤ 0.1%, 10 times lower than the general standard, avoiding cross contamination between samples

2. Strong multi-color fluorescence detection ability:

It can reduce the sample size and provide more information for each test sample

Dual laser and triple laser for six or eight color analysis

3. Strong signal processing and analysis abilities:

Digital electronic systems eliminate dead time in electronic systems

The fluorescence compensation adjustment between lasers is extremely simple, accurately performing fluorescence compensation in both online and offline modes for both internal and external lasers

4. FACSCantoIIclinical software equipped:

Implemented a comprehensive analysis of tubular lymphocyte subpopulations

Capable of automatically setting gates, calculating results, and generating experimental reports for TBNK and HLA-B27 modules

Easy to operate, functional*


IIBD-FACSCanto flow cytometerTechnical parameters:

parameter name parameter value
1) Detection performance, fluorescence detection sensitivity FITC < 100MESF, PE < 50MESF
Fluorescence resolution PI staining CEN samples, G0/G1 phase full peak width PI Area CV<2.0% (488nm laser)
Fluorescence linearity PI staining of CEN samples, with a bi adhesive/single-cell ratio of 2 ± 0.05 (488 nm laser)
Scattered light sensitivity Can effectively distinguish fixed platelets from noise signals, distinguish bacteria from 0.5micron microspheres
Analysis speed 10000 cells per second
Detect cell size 0.5μm-50μm
compensation method Automated, manual, or offline compensation
2) Optical path system excites the optical path Laser fixed calibration, no need to adjust the optical path
Laser specifications 488nm laser, 633nm laser
Detection method Quartz cup flow cell, coupled with fluorescent objective lens through optical glue coupling
Optical path guidance system Fixed optical path system, laser and fluorescence conduction adopt all fiber optical path
Fluorescence collection Octagonal and Triangular Continuous Reflection Collection System
Fluorescent filter 488nm laser
633nm laser 660/20nm、712/21nm、780/60nm
Detector configuration 8 detectors in total
3) Signal processing signal capture mode Digital signal
Electronic dead time 0
Data resolution 262,144channel
Analyze parameters There are a total of 8 signals, including 2 scattered light signals and 8 fluorescence signals
Fluorescence compensation Compensation between arbitrary fluorescence (hardware compensation, software offline compensation)
Signal pulse processing Pulse signal height, area, width detection, and ratio detection with arbitrary parameters
time parameter Can be combined with any parameter for dynamic detection
threshold Threshold values can be set for any laser with any parameters
4) Flow rate control of liquid flow system 10μl/min-120μl/min
Sample dead volume 30 μ l (using standard 12'75mm test tube)
Quartz cup specifications 430mm ´ 180mm
Fluid flow vehicle system There are sheath liquid tank, waste liquid tank, and two cleaning solution tanks
Sample cross contamination rate ≤ 0.1%
5) Data Management System Workstation HP Z210 Workstation
data storage Hard drive above 500GB
memory 2GB
monitor Two 19 inch LCD displays
printer HP Color Laser Printer
Data file format Flow cytometer standard FCS 3.0
software package Flow based multifunctional acquisition and analysis software
Clinical testing software FACSCanto Clinical
DNA analysis software Fit