Automatic Acid Value TesterOverview and Scope of Application:
The instrument adopts the principle of potentiometric titration, in which the indicator electrode, reference electrode, and auxiliary electrode are immersed in the test solution. Changes in the concentration of the test substance in the solution will cause a sharp change in the potential of the indicator electrode. After reaching the titration endpoint, the concentration of the test substance can be calculated based on the volume of the standard solution consumed. The instrument is suitable for determining thiol sulfur in hydrogen sulfide free jet fuel, gasoline, kerosene, and light diesel oil. The instrument consists of three parts: hardware circuit, titration device, and PC. With the support of software, it can achieve the determination of acid value, thiol sulfur content, and alkaline nitrogen content in petroleum products.
Automatic Acid Value TesterApplicable standards:
Compliant with standards such as GB/T9725 or GB/T1792, ASTMD3227, or GB/T7304, GB/T264, ASTMD664, or SH/T0162; (This machine can perform oxidation-reduction titration, complexometric titration, acid-base titration, precipitation titration, etc.)
★ Main performance characteristics and parameters:
☆ Windows operating system, using human-machine dialogue mode for operation;
☆ Adopting Swiss imported titration units, with stable and reliable performance and low noise;
☆ Titration function: automatic cleaning, automatic fluid replenishment, constant value addition;
Multi parameter setting and correction make the analysis of different types of samples more convenient;
☆ Analysis system: automatic endpoint discrimination, automatic filtering of false endpoints, multi parameter setting and correction;
Suitable for the analysis of alkaline nitrogen in various light and dark colored oils in oil products, automatic storage and printing of titration results and data;
☆ Dual high impedance input, multi electrode system, stable and reliable electrode potential;
☆ Data processing: It has the function of automatic calculation of concentration and content. The working curve is automatically fitted once and twice, with automatic correction function;
☆ Standard addition method. Repeatable testing can be conducted 1 to 20 times, automatically calculating the mean, standard deviation (SD), and relative standard deviation (RSD)
Measurement range: 0.0003% to 0.01% (m/m),
☆ Potential measurement range: 0 to ± 1999.5 mV;
☆ Basic: 0.1% ± 0.5 Input impedance: ≥ 1 × 1012 Ω
☆ burette volume: 10mL, accuracy: ± 0.1% F · S;
☆ Data communication interface: RS232
☆ Specification: 430mm × 430mm × 250mm, Weight: 14Kg;