Atmospheric pre concentrator (free of liquid nitrogen)

NegotiableUpdate on 12/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The BCT 990MT atmospheric pre concentration instrument (liquid nitrogen free) adopts an electronic refrigeration three-stage trap design, which can pre concentrate volatile and semi volatile organic compounds such as polar, non-polar, active sulfur, nitrogen compounds, etc. below C20 in the sample.
Product Details

BCT 990MTAtmospheric pre concentrator (free of liquid nitrogen)Adopting an electronic refrigeration three-stage trap design, it can pre concentrate volatile and semi volatile organic compounds such as polar, non-polar, active sulfur, and nitrogen compounds below C20 in the sample. After concentration and removal of substances such as water, N2, CO2, etc., the sample is subjected to thermal desorption focusing for gas separation and detection. With one injection, hundreds of VOCs can be accurately detected.

大气预浓缩仪(免液氮)

• Liquid nitrogen free design

Dual tank metering technology

Not affected by sample matrix - using pressure measurement method, abandoning traditional MFC measurement, pressure measurement is not affected by sample matrix, and any matrix measurement is accurate.

Wide injection range - The dual tank design has high injection accuracy, with a standard injection range of 5-1000ml. It has high accuracy for both high concentration small volume injection and low concentration large volume injection.

Fast injection speed - The injection flow rate is automatically adjusted, with a flow rate as low as 5ml/min or below. The injection flow rate can achieve a capture flow rate of over 150ml/min, with an injection volume of 300ml and an injection time of less than 3min.

• Independent focusing trap

Injection without diversion - independent focusing trap, no diversion loss during injection, improving detection limit level.

大气预浓缩仪(免液氮)

BCT 990MTAtmospheric pre concentrator (free of liquid nitrogen)Adopting an electronic refrigeration three-stage trap design,Capable of detecting polar, non-polar, active sulfur, and nitrogen compounds below C20 in the samplePre concentration of volatile and semi volatile organic compounds.The sample is concentrated, and after removing substances such as water, N2, CO2, etc., it is pyrolyzedAbsorption focusing enters the gas separation detection, and can accurately detect hundreds of samples with one injectionPlant VOCs.