1、 Product Introduction:
JWD-2000ZPAtmospheric plasma cleaning machineThat shouldAtmospheric plasma cleaning machinePlasma cleaner is a domestically developed atmospheric plasma cleaning machine that uses a highly stable phase-shifting full bridge soft switching circuit and a stable analog communication data transmission method. It can achieve unified monitoring by the central control system, making the cleaning effect more stable and durable, enhancing anti-interference performance, reducing failure rates, controlling maintenance costs, increasing production capacity, and effectively reducing production costs.

2、 Principle Introduction
By applying an electric field to the process gas, it ionizes into plasma. The "active" components of plasma include ions, electrons, atoms, free active groups, excited state nuclides (metastable states), photons, etc. Plasma treatment is the process of utilizing the properties of these active components for physical and chemical reactions such as oxidation, reduction, cracking, cross-linking, and polymerization to alter the surface properties of samples, thereby optimizing material surface properties and achieving cleaning, modification, etching, and other purposes.
3、 Instrument construction

Structure of atmospheric plasma cleaning machine: composed of a high-voltage power generator and a plasma generating device spray gun.
4、 Instrument parameters
JWD-2000 power specification parameters | |||
serial number |
Category |
parameter |
Remark |
1 |
input power |
Single phase 220V/AC50/60Hz、10A |
Ground wire < 4 Ω |
2 |
Input gas source |
CDA/N2 (0.3-0.6Mpa) inlet pipe diameter: Φ 8 |
Oil free and water free |
3 |
output power |
300-1300 W |
Determine based on the use of a spray gun |
4 |
output accuracy |
±5% |
The current power value determines |
5 |
power factor |
≥50% |
The higher the power factor, the higher the power efficiency |
6 |
Output gas pressure |
80-300Kpa |
According to the settings for using the spray gun |
7 |
operating frequency |
20KHz-35KHz |
According to the settings for using the spray gun |
8 |
working method |
Constant pulse width |
Analog Control |
9 |
external interface |
PLC-IO |
Please refer to the instruction manual for detailed function introduction |
10 |
Communication line length |
200±5mm |
Optional welding free joint |
11 |
Start stop interval time |
Start: 3S, Close: 3S |
Short interval time will reduce equipment stability |
12 |
Equipment Utilization Rate |
Continuous operation of over 95% |
The utilization rate represents the stability of the equipment |
13 |
Working environment temperature |
-20 ~ 35℃ |
Nothing |
14 |
Dimensions (mm) |
L457xW395xH159mm |
Please refer to the appearance dimension diagram for details |
15 |
Power weight |
15KG |
Nothing |
16 |
Configure space |
Good ventilation, leaving over 200mm of heat dissipation space on both sides and 200mm of wiring space behind |
|
17 |
Interference precautions
|
Please separate the plasma power supply from the PC power supply Plasma equipment (power supply, gun head, high-voltage cables) should be separated from the PC host and screen by at least 20cm ※ It is necessary to connect an independent grounding (cable with an area of 4mm ² or more) |
|
18 |
detection function |
Equipped with air pressure detection and rotation detection (rotating spray)Gun JuBackup), motherboard temperature detection function |
|
19 |
protection function |
Equipped with protection against low and high air pressure, as well as protection against low rotational speed |
|
Spray gun accessories

5、 Product advantages

6、 Application Fields

7、 Specification requirements
Factory requirements | |
Power requirements |
Single phase AC220V, 50/60Hz, 10A |
Grounding requirements |
The power box needs to be connected to the grounding wire of the machine platform (Ground wire thickness of 4mm or more, grounding resistance<0.6 Ω, the machine needs to reserve a separate ground wire interface) |
Gas source requirements |
Tracheal requirement: PU trachea 8mm Gas requirements: CDA/N2, pressure 0.3-0.6Mpa, Solid particle size<=0.1um, oil content<=0.01mg/m ³, pressure dew point below -40 ° C |
Exhaust pipe |
Flow rate: 5m ³/min, the material of the gas discharge pipeline needs to be corrosion-resistant |
8、 Enterprise strength

9、 Transaction customer
Dedicated to providing users with professional surface treatment and testing solutions as a whole