-
E-mail
616528239@qq.com
-
Phone
18016328091
-
Address
Room 1007, Building B, Yinhai Building, No. 250 Caoxi Road, Xuhui District, Shanghai
Shanghai Lidian Technology Co., Ltd
616528239@qq.com
18016328091
Room 1007, Building B, Yinhai Building, No. 250 Caoxi Road, Xuhui District, Shanghai

Product Name: Artificial Lens Imaging Measuring Instrument
Product model: IOL-IMAGER
IOL-IMAGER artificial lens imaging measuring instrument is used for mechanical performance testing of artificial lenses in YY 0290.3-2018. It is a professional optical instrument designed specifically for geometric appearance observation and measurement of artificial lenses, suitable for research and development, production quality control, and compliance testing scenarios.
Advantages of the IOL-IMAGER artificial lens imaging measurement instrument:
Four mode lighting: providing multi-directional lighting to meet different observation needs;
Three axis mobile system: precise adjustment of measurement position;
Thermostatic water bath: simulates the intraocular environment to ensure measurement authenticity;
Four sets of specialized fixtures: suitable for various measurement scenarios;
High speed transmission: USB 3.0 interface+5-megapixel camera, efficient data acquisition.
The key functions of the IOL-IMAGER artificial lens imaging measurement device are:
Compliance testing in accordance with YY0290.3/ISO11979-3 standard: covering Appendix B (axial displacement under compression), C (optical eccentricity after compression), D (optical tilt angle after compression), E (contact angle after compression);
Geometric measurement: precise measurement of parameters such as diameter, thickness, and loop size;
Defect observation: Inspect surface/internal defects, evaluate centrality, polishing quality, etc.
Main specifications and parameters:
Range of movement of intraocular lens fixture:
The movable range of X-axis (left-right movement) is not less than 60mm
Z-axis (up and down focusing) movement range not less than 10mm
Camera movement range:
The range of forward and backward movement shall not be less than 50mm
Up and down movement range not less than 55mm
Provide four independently controlled directional lighting modes:
Front lighting, back lighting, side lighting, and oblique lighting
Lighting brightness: The brightness of backlighting and side lighting includes three adjustment functions: strong light, weak light, and off
Lighting angle: The angle of side lighting and oblique lighting has an adjustable function
Resolution: 5 million pixels (2592 * 1944)
Equipped with a heating device, the temperature of the testing environment for artificial intraocular lenses can be controlled
Temperature control range: at least including room temperature to 50 ℃;
Dimensional measurement indication error: not exceeding ± 0.003mm
Optical magnification: 0.3 times
Lens field of view: not less than 13.0mm × 9.6mm
Clamping of artificial lens fixture: travel not less than 13mm
Provide calibration scales for size testing of artificial intraocular lens imaging devices, with an accuracy of no more than ± 0.01mm
Artificial intraocular lens fixture calibration plate: including two specifications of 10mm and 11mm, with an accuracy of no more than ± 0.01mm