purpose
Artificial board rolling wear testing machineIt is developed for the testing of "surface wear resistance" of various types of artificial boards and decorative artificial boards, in accordance with the standards GB/T 17657-2013 Physical and chemical performance test methods 4.42~4.44 Surface wear resistance test methods 1-3, GB/T 17657-2022 Physical and chemical performance test methods 4.45~4.47 Surface wear resistance test methods 1-3. It is an ideal testing equipment for quality inspection departments and artificial board production enterprises at all levels, and can provide you with accurate test results.
Test principle
Artificial board rolling wear testing machineBefore starting the test, the operator places the sample with a clean surface on the turntable and clamps it tightly; After installing the grinding wheel on the machine, set the counter to zero and gently place the grinding wheel on the specimen. Turn on the vacuum cleaner and the test piece can rotate for testing. The rotation of the test piece on this machine is driven by a motor, and the buttons on the control panel control the motor and counter, etc.
The main specifications are as follows:
1. Test force: 5N
2. Accuracy of test force: ± 0.2N
3. Test piece rotation speed: 60 ± 2r/min
4. Test piece size (mm): Length=(110 ± 2) * (110 ± 2) or Φ 120 ± 2
5. Dimensions (width * length * height): 24 * 35 * 31cm
6. Weight: 25kg
Notes:
1. When using this product, carefully read the technical manual, familiarize yourself with the technical specifications, working performance, usage methods, and precautions, and strictly follow the prescribed steps in the instrument manual for operation.
2. Personnel using the equipment for the first time must operate it under the guidance of skilled personnel and only after mastering it can they perform independent operations.
3. The layout of instruments, equipment, and devices should be reasonable, neatly arranged, easy to operate, observe, and record.
Before powering on electronic instruments and equipment, ensure that the power supply voltage meets the specified input voltage value of the instrument and equipment. Instruments and equipment equipped with three wire power plugs must be plugged into power sockets with protective grounding to ensure safety.
When using the device, its input signal or external load should be limited within the specified range, and overloading operation is prohibited.
6. The equipment should not be operated and used in magnetic or electric fields. Shielding measures must be taken to prevent damage to the instrument or equipment or a decrease in measurement accuracy.
After the instrument malfunctions, it should be repaired by professionals. Using accessories not recommended by the manufacturer can cause certain quality problems.