Anshengneng EUCHNER Safety Switch TP Series Electromechanical

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Anshengneng EUCHNER Safety Switch TP Series Electromechanical $r $nTP Series Safety Switch, M20 x 1.5 Cable Inlet, Contact for Door Position $r $n 3 M20 x 1.5 Cable Inlet $r $n Contact for Door Position $r $n Auxiliary Unlocking Device $r $n Electrical Lock

Product Details

Anshengneng EUCHNER Safety Switch TP Series Electromechanical

Front end mechanical release

Optional door monitoring contact

Improved the level of over travel

Cable entrance M20x1.5mm. 2 normally closed+1 normally open+1 normally closed contact configuration Electromagnetic valve operating voltage: 24VAC/VDC. Slow action switch contact

TP series safety switch with door monitoring contacts

Front auxiliary unlocking device

Equipped with door monitoring contacts

Enhanced horizontal overtravel

Approaching direction

horizontal and vertical

Can be adjusted with a 90 degree increase

Higher travel capability when approaching horizontally

Working voltage of electromagnetic coil

AC/DC 24 V +10%, -15%

Locking type

TP3 is unlocked by powering on, and spring force locking is unlocked by powering on the electromagnetic coil

Switching element

2131 Slow acting switch contacts, 2 normally closed+1 normally open+1 normally closed (door monitoring contacts)

Auxiliary unlocking device

Used to unlock the locking function with the assistance of tools. To prevent modification, the auxiliary unlocking device is coated with sealing paint for sealing.

Electrical connection value

hedgingmax. 4 A gG

power consumption8 W

Connecting cross-sections0.34 . .. 1.5 mm²

Rated insulation voltage Ui250 V

Rated impulse voltage Uimp2.5 kV

Utilize categories

DC-134A 24V

AC-154A 230V

Working voltage of electromagnetic coil

AC/DC24 V -15% . .. +10%

Duty cycle of electromagnetic coil100 %

Switching voltage

Minimum (at 10 mA)12 V

Switching current

Minimum (at 24 V)1 mA

Thermal rated current Ith4 A

Mechanical values and environment

Starting speedmax. 20 m/min

connection type

3 xM20 x 1.5

Number of normally closed contacts at the door position1

Number of normally open touch points for door lock monitoring function1

Number of forced disconnection contacts for door lock monitoring function2

pull-out force20 N

Trigger force10 N

Installation directionany

Storage temperature-25 . .. 70 °C

mechanical life1 x 10 ⁶

Fixed force10 N

Switching principleSlow acting switch contact