1. CLD 844CM h high concentration nitrogen oxides/Ammonia gas analyzer
CLD 844 CM hThe specifications adopt modular design, and the most suitable instruments can be customized according to customer needs. Built in NH3 and NO2 conversion devices enable simultaneous monitoring of high concentration nitrogen oxides and ammonia gas. Mainly used for nitrogen oxide analysis in high-purity special gas standard gas.
New Features and Benefits
·Built in dual reaction chamberAdopting a dual reaction chamber device to simultaneously measure the concentrations of nitrogen oxides and ammonia in the gas.
·Pipeline heating deviceThe sample gas pipeline is equipped with a heating device to avoid the production of ammonium salts. Ensure the accuracy of the measurement.
·Adequate response and high efficiencyBuilt in high-voltage ozone generator can generate high concentration ozone and improve reaction efficiency.
·Avoid secondary pollutantsBuilt in high-temperature ozone decomposition device (replacing activated carbon adsorption), maintenance free, no consumables, avoiding secondary pollution.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 844CM hSpecifications
·Measurement item: Can simultaneously measure and display NOx/NH3/NOx amines or NO/NO2/NOx
·Measurement range: 0.5-500ppm, divided into four sections, freely adjustable measurement range
·Extremely fast full-scale time:<1 second (T90)
·Gas flow rate: 1.2 l/min
·Conversion device: Built in NH3 and NO2 converters
·Minimum detection value: 0.025ppm
·Gas pipeline heating: can be heated to 190 ℃
2、 CLD 824MM DR dual inlet high concentration nitrogen oxide analyzer
CLD 824MM drThe specification adopts two sets of NO2 conversion devices, independent sample gas pipelines and reaction chambers, which can measure two independent sample gases simultaneously. Mainly used in flue gas monitoring.
New Features and Benefits
·Built in dual reaction chamberUsing a dual reaction chamber device, measure the concentration of nitrogen oxides in two independent sample gases simultaneously.
·Adequate response and high efficiencyBuilt in high-voltage ozone generator can generate high concentration ozone and improve reaction efficiency.
·Avoid secondary pollutantsBuilt in high-temperature ozone decomposition device (replacing activated carbon adsorption), maintenance free, no consumables, avoiding secondary pollution.
·Pressure compensation deviceEquipped with an automatic pressure compensation device, it will not affect the measured value due to pressure changes.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 824MM drSpecifications
·Measurement item: Can simultaneously measure the NOx values of two different source gases
·Measurement range: Different measurement ranges of 0.5-500ppm/5-5000ppm, each group can be divided into two sections, and the measurement range can be freely set
·Extremely fast full-scale time:<1 second (T90)
·Gas flow rate: 1.2 l/min
·Conversion device: Built in two sets of NO2 converters
·Minimum detection value: 0.025ppm/0.25ppm
·Automatic pressure regulation: 600~1200mbar