- Phone
-
Address
No. 5 Zhengxing Road, Caozili Town, Wuqing District, Tianjin City
Tianjin Zhongke Haoling Experimental Instrument Co., Ltd
No. 5 Zhengxing Road, Caozili Town, Wuqing District, Tianjin City
American Maice Underground Pipeline Detector vLoc3-LiteTechnical specifications
American Maice Underground Pipeline Detector
1、 Main purpose:shouldBy using the principle of electromagnetic induction, the position, direction, and depth of underground oil and gas pipelines, metal pipelines, cable communication pipelines, and other pipelines can be quickly and accurately detected without damaging the ground cover.
2、 Technical specifications requirements:
2.1: Receiver
project |
parameter |
✳color display screen |
480*272Pixels,16Bit pixel, high precisionLEDdisplay screen4.3inchSuitable for sunlightuse |
battery |
Alkaline battery box usage6Section StandardsAAAlkaline battery, optional rechargeable lithium battery |
battery life |
-Alkaline battery –in21 ºCIt can usually be used continuously12hour Lithium battery –in21 ºCIt can usually be used continuously12-27Hour (all backlight on). |
Displayed information |
-signal strength-Mobile attention and numerical values -Mode indication(“Peak mode”, “Valley mode”and“Peak Arrow”positioning mode) -Compass: Direction indicator -Signal direction -Route positioning –Depth and current measurement -Gain level(unitdB) -Battery status,Speaker volume,operating frequency,Configure menus and submenus |
Internal data log |
-at least5000Ten thousand records -Each positioning point stores all data, including depth, current, mode, gain setting, and frequency -Can be stored as.kml,.xls.txt. csv.shp.format |
Data memory |
-4GB |
operating frequency |
Power50TheRadioThe50HzTheCP100The128HzThe256HzThe32.8kHzThe512HzThe640HzThe8.19KHzThe8KFFTheCATVThe32.8kHzThe65.5kHzThe83.1kHzThe131kHzThe200kHz |
✳Using a single undistorted device |
-measurement accuracy -Accuracy of positioning and depth measurement±2.5% -Accuracy of current measurement±2.5% |
Transmitter compatibility |
Loc-150Tx, Loc-25Tx,Loc-10Tx, Loc-5Tx, Loc-1Tx |
✳Distortion signal recognition |
Red, blue, and green color codes display distortion levels |
Multiple detection modes |
-Classic positioning mode -Tracer probe mode |
✳ Classic positioning mode |
-peak -trough value -Peak Arrow -Kuanfeng -Double Valley Diagram -Omnidirectional peak value -Wide peak in all directions |
✳ Tracer probe mode |
PEPipe path detection Real time pointing to the position of the tracking probe |
protection level |
IP65andNEME4 |
software upgrade |
Free software upgrade, no need to change hardware |
✳ detection range |
0~30m |
warning function |
Warning for overhead cables Warning of excessive swinging Warning for shallow burial depth Signal overload warning |
Self-check function |
Equipment calibration can be carried out on-site at any time without the need to return to the factory for calibration. |
Operating Temperature |
-20℃~+50℃ |
quality certification |
The product complies withCEandFCCCertified, passedISO9001 |
2.2: Transmitter
project |
Technical parameters of transmitter |
output frequency |
640HZ/8.19KHZ/8.44KHZ/32.8KHZ/82.5KHZ/131KHZwait40Multiple frequencies |
Mixing output |
The transmitter supports simultaneous output of two and three frequencies of signals |
output power ✳ |
Output power not less than10wThe maximum output current shall not be less than999mA |
battery |
Alkaline battery working time>20Optional rechargeable lithium battery available for hours |
software upgrade |
throughUSB2.0Automatic interface upgrade without the need for hardware modifications |
quality certification |
The product complies withCEandFCCCertified, passedISO9001 |
3、 Data transmission:
①Through specialized software,Connect the device with a data cable and export the corresponding data in the following format:kml,.xls.txt .shp.Waiting format
②Export different formats according to different requirements. When viewing pipeline routing reports, they can be exportedKMLDisplay the data on the map.
③If data analysis is required, it can be exportedExcelPerform a detailed analysis of the pipeline data based on the table data.