- Phone
-
Address
No. 5832 Huyi Road, Jiading District, Shanghai
Shanghai Hanchao Testing Equipment Co., Ltd
No. 5832 Huyi Road, Jiading District, Shanghai
Equipment nameAirflow test bench
Model: HC-KTF-3000L
1、 Main parameters and functions of the equipment
This test device is used for thermal performance analysis of power supplies and meets the requirements of standard GB/T1236-2000 (equivalent to ISO5801). Refer to the American AMCA210 standard.
Plan Overview:
According to GB/TRequirements for 1236-2000
technologyindicator
Wind volume range of the tested fan:70~3000 m³/h; Resolution 0.1m ³/H
Wind tunnel size (approximately): W860mm * H860mm * L3250mm-
Measurement accuracy: 1.5%~2%;repetitivenessprecision:±1.5%
Environmental temperature: -20~60 ℃ (measured value)
Temperature testing accuracy: 0.1 ℃
Static pressure:-500~2000Pa; Differential pressure: -200-1000Pa; Resolution: 0.1Pa;
Equipment control parameters: outlet pressure; Differential pressure on both sides of the nozzle; Auxiliary variable frequency fan;
Equipment measurement parameters: wind tunnel static pressure, pressure difference on both sides of the wind tunnel nozzle; Wind tunnel measurement of chamber temperature, humidity, and atmospheric pressure;
Software environment: Using a universal database environment to reduce costs
Database environment: MY SQL
Programming language: C #, operating system; XP or Wind0ws 7
10Device description:Control cabinet, 1 wind tunnel, 1 auxiliary fan with variable frequency control, static pressure pipe, and air duct.
11 Random attachment description:
Equipment operation manual, overall introduction of the equipment (external and internal), certificate of conformity, exterior design drawing of the box body
12 Installation method description:Voltage 380V, power 3.0KW.
13 tested fans: AC, 2KW;
Airflow test benchHC-KTF-3000L
2、 Control scheme
This test bench adopts a blowing wind tunnel to test the performance of the fan. The specific plan is as follows:
| plan | |
| Program Name | Automatic adjustment control |
| Blowing temperature | room temperature |
| Nozzle selection method | automatic control |
| control parameters |
Wind tunnel static pressure Nozzle pressure difference Tested fan voltage |
| measurement parameters | Wind tunnel static pressure |
| Nozzle pressure difference | |
| Tested fan voltage | |
| Current of the tested fan | |
| Wind tunnel temperature | |
| Wind tunnel humidity | |
| atmospheric pressure |
3、 Control parameters(Control parameters in fully automatic control schemes, measurement parameters in other schemes)
Wind tunnel static pressure (constant static pressure)
Static pressure transmitter: precision micro pressure transmitter, -500Pa~2000Pa/1-5V (accuracy 0.075%)
Control: PID
Data recording: collected to the computer through a data collector
Nozzle pressure difference (constant air volume)
Differential pressure transmitter: precision micro pressure transmitter, range -200~1000Pa /1-5V (accuracy 0.075%)
Control: PID: Output to control the opening degree of the electric air valve!
Data recording: collected to the computer through a data collector
4、 Measurement parameters
1. Wind tunnel temperature
Measurement range: relative temperature -20~80 ℃-
Measurement accuracy:±0.1℃
Signal converter: -20~60 ℃/ 1~5V DC
Data recording: collected to the computer through a data collector
2. Wind tunnel humidity
Measurement range: relative humidity0~100%RH
Measurement accuracy: relative humidity±3%RH
Signal converter: 0-100%/ 1~5V DC
Data recording: collected to the computer through a data collector.
3. atmospheric pressure
Measurement range: 80-120kpa;
Pressure transmitter: 0.2%, Drucker, 4-20mA,DCoutput
Data recording: collected to the computer through a data collector
5、 Equipment
1. Optional blowing/suction, convertible type
External dimensions: approximately 750W×750H×2650L mm
Rectifier network
Internal dimensions:About 750W×750H
Rectifier network
spray mouth 6a
Fan: Multi blade centrifugal fan, with a total pressure of approximately 2000 Pa, Air volume 3500m3/hAnd 1500 static pressure fan.
Motor: 2.2kWFrequency converter:2.2KW
2. control cabinet
Switches, indicator lights, digital displays; Emergency stop switch and frequency converter fault alarm