| ²Product Specification | File number:B-608749CN | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Name: Breathing Air High Pressure Compressor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Model:GMC F500S | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1Product function and scope of use: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| GMC F500S air respirator inflation pumpThrough efficient compression and purification treatment, a high-pressure clean air source that meets domestic and international breathing air standards is provided. Its filtration system can effectively remove impurities such as moisture and oil particles from the gas, ensuring pure and safe air. The equipment is suitable for fields such as fire rescue, diving operations, industrial enclosed space operations, chemical protection, medical first aid, aerospace, etc. that require strict requirements for respiratory gas source pressure and cleanliness. It can stably output high-pressure gas that meets human respiratory needs in complex environments. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IIProduct composition and functions: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| GMC F500S air respirator inflation pumpAdopting a vertical layout,WithThe main engine of the F-series piston compressor is divided into two configurations: four stage compression (maximum 40MPa) and five stage compression (maximum 50MPa). The three-phase motor below forms a stable structure with the main engine, and the outer shell has both air guiding and heat dissipation functions as well as physical protection. Functionally equipped with a mechanical control system, it supports one click start stop, operation timing, and fault display. It also has an automatic sewage function to regularly remove oil stains from the separation cylinder. The matching filter cylinder efficiently filters gas impurities to ensure that the output air meets breathing standards,The overall structure is compact and has high functional integration, balancing ease of operation and reliability of gas purification. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| IIITechnical parameters: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4Product Configuration: | |||||
| l4.1 Standard Configuration: | |||||
| l4.1.1 Function configuration | |||||
| ²ratedworking pressure:35MPa | ²safety valve36.5MPa | ²Environmentally friendly plastic powder coating | |||
| ²Maximum pressure:36.5MPa | ²Green yellow with black | ²Electronic User Manual | |||
| l4.1.2 Standard Configuration | |||||
| ²Button type controller ◆ | ²Automatic sewage discharge ◆ | ||||
| lone-clickStart-stop lruntime lPhase sequence alarm lLow oil pressure alarm
| lRegularly discharge oil stains from the separation bucket | ||||
| ²Silent Design ◆ | ²filter cartridge ◆ | ||||
| lOverall silent design lnoise≤80 lThe cover design is convenient and quick to disassemble leasy to maintain lThe operation panel conforms to ergonomics
| lFilter the moisture in the gas
| ||||
| Random accessories | |||||
| ²filling funnel # | ²Paper instruction manual # | ²certificate of conformity # | |||
| ²Wrench lever-200mm # | ²Oil drain pipe assembly # | ²Oil filter replacement tool # | |||
| consumables | |||||
| ²Lubricating oil for high-pressure compressor # | ²Low temperature lubricating oil for high-pressure compressor # | ²oil filter cartridge-QS110T ◆
| |||
| vbelow zero15Above ° C, breathable for use
G62B-L25H-0020 | vbelow zero25Above ° C, breathable for use
G62B-A35H-0010 |
G07A-F30L-0133 | |||
| ²Activated carbon filter cartridge-HL40#
| ²15HP intake filter element ◆
| ||||
|
G11B-HL40-FD00 |
G10B-KL30-1000 | ||||
| lCustomer selection: | |||
| power | |||
| ○11KW three-phase motor | ○15KW three-phase motor | ||
| controller | |||
| □β Controller◆ | □PLC controller◆ | ||
| lone-clickStart-stop lmaintenancedisplay lLCD (Liquid Crystal Display) lruntime
G02C-F33I-0030 | lAuto Start-Stop lMonitor the operational status lMaintenance Reminder lImage shows lruntime lAlarm reminder (overcurrent alarm Phase sequence error alarm, phase loss alarm Alarm for high ambient temperature, alarm for high oil temperature Low oil pressure alarm, high oil temperature alarm High pressure alarm at all levels, pressure transmitter disconnection alarm) lOther custom features
G02C-F33I-0040 | ||
| Other optional functions | |||
| □humidity controller(Implement filter maintenance reminder function) ◆
G02C-E18I-0012
| □ Custom appearance color◆ | ||
|
| |||
| □ Final pressure20MPa◆ | □ Final pressure40MPa◆ | ||
| □ Final pressure50MPa◆ | |||
| brand information | |||
| ○ standard | ○ neutral | ○ 定制 | |
| lOptional parts | |||
| □Activated carbon filter cartridge-HL40 # |
| ||
| ²Effectively filtering carbon monoxide
G11B-HL40-FD00 |
G05B-CA01-2300 | ||
| □ Inflatable valve with meter # | □1.2-meter-long high-pressure hose # | ||
| ² ²Evacuate residual gas in the pipeline ²display pressure
G02C-C06I-0010 |
| ||
| □Medium repair package-F4.1型host | □major overhaul kit-F4.1 type host | ||
Note: marked withThe "○" option is mandatory, while the "□" option is optional; Items marked with "◆" require installation on the product, while items marked with "#" do not require installation on the product at the time of shipment
| 5Picture and Size: |
| lillustration |
|
|
| lStandard Outline Dimensional Drawing: |