Welcome Customer !

Membership

Help

Shanghai Zhenkang Medical Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Advanced fully automated computerized cardiopulmonary resuscitation simulator

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Advanced fully automated computerized cardiopulmonary resuscitation (CPR) simulator. CPR, also known internationally as CPR, is not only a professional emergency medicine, but also the core content of modern rescue. It is the most important first aid knowledge and skills. It is an effective first aid measure taken in critical situations. In daily life, healthy individuals who experience cardiac arrest (such as electric shock, drowning, poisoning, high-altitude work, traffic accidents, travel accidents, heart disease, myocardial infarction, natural disasters, accidents, etc.) must resort to measures such as airway release, chest compressions, artificial nose breathing, external defibrillation, etc

Product Details

Advanced fully automated computerized cardiopulmonary resuscitation simulator Advanced fully automated computerized cardiopulmonary resuscitation simulator

The ZK/CPR490S advanced automated computerized cardiopulmonary resuscitation (CPR) simulator is the latest emergency training model developed to improve trainees' emergency response capabilities in the event of disasters or accidents, in accordance with the requirements of the American Heart Association (AHA) 2015 International CPR&ECC Guidelines.

The simulated human has obvious anatomical features, realistic hand feel, uniform skin color, realistic shape, and beautiful appearance.
Simulated vital signs:
In the initial state, the simulated human pupil is dilated and there is no pulsation in the carotid artery.
During the compression process, simulate the passive pulsation of the human carotid artery, with a pulsation frequency consistent with the compression frequency.
After successful rescue, the simulated human pupils returned to normal and the carotid artery began to pulsate autonomously.
Pupil dilation and carotid pulsation can be turned on and off by a switch.
Can perform artificial respiration and extracardiac compression. Standard airway opening can be performed, and the airway indicator light will turn on.
Three operation modes: CPR training, mode assessment, and practical assessment.
Method 1: Training ModeIt can be trained by pressing and blowing.
Method 2: Assessment mode, within the set time, according to 2015International standard for cardiopulmonary resuscitation, correct compression and blow countComplete 5 loop operations at a ratio of 30:2.
Method 3: Practical mode, where the teacher can set the operating frequency, operating time range, pressing frequency, blowing frequency, cycling frequency, accuracy, etc. on their own.

Controller display screen function:
Electronic monitoring: The electronic indicator light displays the open and pressed parts of the monitored airway. The correct and incorrect counts of artificial respiration and chest compressions.
■ Voice prompt: Throughout the training and assessment process, voice prompts can be turned on and off, and the volume can be adjusted.
■ Barcode display blowing volume: The correct blowing volume is 500-600ml-1000ml:
When the blowing volume is too low, the barcode will be yellow.
When the blowing volume is appropriate, the barcode is green.
When the blowing volume is too large, the barcode will be red.
The tidal volume blown in is too fast or too large, causing gas to enter the stomach and the indicator light to display; Digital counting display; Error language prompt;
The barcode displays the pressing depth, and the correct pressing depth is 5-6cm:
When the pressing depth is too low, the barcode will turn yellow.
When the pressing depth is appropriate, the barcode will turn green.
When the pressing depth is too large, the barcode will turn red.
■ The operation time can be set by oneself in seconds.
Operating frequency: The standard for 2015 is 100-120 times per minuteYou can set the value yourself.
■ Power status: Using a 220V power supply, the output power is 12V after being stabilized by a voltage regulator.

Printer function:
Print the operation process after the operation is completed.
The transcript covers consciousness judgment and emergency callsPulse examination, respiratory examination, removal of foreign objects, operating method, operating frequency, ratio of compression and blowing, number of cycles, number of compressions and blowing in each cycle, correct compression/Number of errors, reasons and frequency of incorrect pressing, reasons and frequency of correct/incorrect blowing, reasons for blowing errors, set time, operation time, and assessment evaluation, etc.

Standard configuration:

One advanced recovery full body human model;

One advanced display controller;

One luxurious hand pulled push type human body hard plastic box;

■ One recovery operation pad;

One 220V external power cord;

One data cable;

■ One box of barrier facial mask (50 pieces/box);

Four sets of replaceable lung capsule devices;

■ One interchangeable leather;

Two rolls of thermal printing paper;

■ 2015International Latest Operation Guide CD1 plate;

One user manual;