Welcome Customer !

Membership

Help

Shanghai Qishu Medical Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Advanced One Year Old Child Cardiopulmonary Resuscitation Tracheal Differential Tube Nursing Simulator

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The advanced one year old child cardiopulmonary resuscitation tracheal intubation nursing simulator (controlled by a tablet computer) is designed based on the anatomical and physiological characteristics of one year old children. It consists of a one year old child simulator, a tablet computer, and operating software, and can conduct training on cardiopulmonary resuscitation, tracheal intubation, basic nursing, and other operations, providing a simple and practical ACLS training tool for emergency physicians.

Product Details

Advanced One Year Old Child Cardiopulmonary Resuscitation Tracheal Differential Tube Nursing Simulator(Tablet control) Designed based on the anatomical and physiological characteristics of one year old children, it consists of a one year old child simulator, a tablet computer, and operating software. It can perform training on cardiopulmonary resuscitation, tracheal intubation, basic nursing, and other operations, providing a simple and practical ACLS training tool for emergency physicians.

Main functions:
The simulator is made of a mixture of thermoplastic and elastic materials, with high simulation accuracy.
The model is wirelessly connected to the tablet, and after successful connection, training and assessment can be conducted through the tablet.
The software can display various feedback during cardiopulmonary resuscitation and differential tube operation.
The software supports uploading courseware.
■ Vital sign simulation: Bilateral dilated pupils compared to normal visual results, with pulsations in the femoral and carotid arteries.
■ Airway management: You can practice tracheal intubation and suctioning through the mouth.
■ Intravenous infusion/puncture: Arm vein, femoral vein, dorsalis pedis vein.
Intramuscular injection: bilateral deltoid muscles, bilateral lateral thigh muscles.
Subcutaneous injection: Subcutaneous injection on the outer thigh.
Bone marrow puncture: Tibial puncture, with obvious surface markers and simulated bone marrow outflow.
■ Microtubule insertion: It can perform gastric lavage, gastrointestinal decompression operations, support abdominal auscultation to detect the insertion position, and after successful insertion, gastric juice can be aspirated.
■ Catheterization: Male/female perineum can be replaced, and male/female catheterization is feasible.
■ Care for colonic, rectal, and bladder fistula openings.
■ Tracheal differential tube training:
·Training mode: Various exercises for tracheal intubation can be performed, and the software will provide corresponding feedback.
·In the assessment mode, the system can score students' operational steps, set scoring parameters, add or delete operational steps, and set scores for each step.
·Equipped with a software scoring module, students' skill operations can be scored item by item, and the results of each operation can be automatically generated and recorded in a log. All data can be scored subjectively and objectively; The subjective part of the scoring table can be modified by the teacher, with scoring parameters set, operation steps added and deleted, and scores set for each step.
·Monitoring module: It has real-time recording function, and the operation content can be saved and reviewed. The teacher can monitor the students' operation situation in real time, review the entire operation process through the operation log, and understand the students' operation error points in the operation results.
CPR training: Three operation methods, including CPR training, simulated assessment, and practical assessment.
·Training mode: Pressing and blowing can be performed, and the software will provide corresponding feedback.
·Assessment mode: Within the specified time, according to the 2020 international cardiopulmonary resuscitation standards, correctly pressing 30 times and correctly blowing 2 times are considered as one correct 30:2 cycle. After completing 5 cycles, the system will give corresponding scores and the evaluator can score again.
·Practical mode: Within the set time range, according to the 2020 international cardiopulmonary resuscitation standards, complete the pre set assessment criteria, and the system will give corresponding scores, and the rater can score again.
The results of cardiopulmonary resuscitation and intubation assessment support export and printing.
Model size: Length 80cm.

Reference configuration:
■ Advanced 1-year-old child cardiopulmonary resuscitation tracheal differential tube nursing simulator: 1 unit
■ Tablet computer: 1 unit
■ Power adapter: 1 unit
■ Disposable breathing facial mask: 1 box
■ Hanging bottle night conveyor: 1 piece
■ Night conveyor bracket: 1 set
■ Syringe: 1 syringe
■ Tracheal differential tube: 1 tube
■ Instruction manual: 1 copy
■ Warranty card certificate: 1 piece