Active toxic wastewater inactivation system

NegotiableUpdate on 04/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The active toxic wastewater inactivation system uses physical and thermal sterilization methods for biological active toxic wastewater ..

Product Details


1、 Product Usage:

Active toxic wastewater inactivation systemMainly used by biopharmaceutical companies, laboratories, research institutes and other units, the live toxic wastewater discharged during the production process must undergo sterilization treatment to kill pathogens before being discharged into the next level sewage treatment system. The system has the advantages of thorough sterilization, high degree of automation, simple operation, good safety, and high reliability.
His name: Biological wastewater inactivation treatment system, live virus wastewater treatment equipment, biological live virus wastewater treatment system, vaccine production live virus wastewater treatment laboratory live virus wastewater treatment system, bacterial wastewater treatment system, bacterial wastewater inactivation system, etc

2、 Working principle:

This product uses physical thermal sterilization method for biologically active toxic wastewater. Steam is directly introduced into the active toxic wastewater, and high temperature is used to denature the bacterial cells or inactivate the coagulase, causing the bacteria to die. The chemical absorption of heat by the virus in DNA and RNA at high temperature leads to bond breakage, thereby inactivating the virus.

3、 Product features:

  1. High biological safety:
    The inactivation tank adopts a dead corner design, and is equipped with an independent temperature measurement system unit and steam heating system, which can ensure that the active toxic wastewater in the inactivation tank is completely inactivated and has no residue;
    The equipment uses imported sterilization filter cartridges, which can effectively filter and treat the exhaust gas of the equipment;
    The external valves of the equipment comply with the 3D sterilization principle, effectively preventing the occurrence of cold spots;
    In addition to the conventional verification method of setting up sampling valves, the system also has an independent inactivation verification device, which facilitates users to re verify the inactivation ability of wastewater.
  2. High reliability:
    The control system adopts intelligent information technology, which can achieve one click start, unmanned operation, and automatic operation;
    The system has considered multiple emergency plans. Can ensure the normal operation of the equipment;
    The inner cavity of the tank body is made of stainless steel plate S30408 for pressure equipment, and the surface of the tank body is polished and then subjected to acid passivation treatment to further improve the corrosion resistance of the equipment;
    Setting a three-level password in the control system can effectively control the operation of the equipment.
  3. Progressiveness of the system:
    The system is equipped with a standard Ethernet communication interface, which can be connected to the central control room for remote real-time monitoring by users;
    The system has powerful memory and self diagnostic functions, and can provide alarm prompts for faults;
    The system is equipped with our company's proprietary proprietary control software, which can directly and intuitively display the operating parameters and status of each device, and can print sterilization process data. At the same time, the system can also display and record the wastewater treatment capacity of each tank;
    The system design includes a device for recycling thermal energy, which can play a role in energy conservation.
  4. Equipment parameters:
    a、 Design pressure: 0.4MPa, design temperature: 150 ℃;
    b、 Working volume of inactivation tank: 1000L, 2000L, 3000L, 5000L~10000L;

  • Main accessories of the collection tank:
Serial Number Material name Material specifications material quantity notes
1 360 cleaning ball 1” 304 1
2 Differential pressure level sensor 304 1
3 thermometer 0~150 ℃ (quick installation type) L=800 304 2
4 Diaphragm pressure gauge 0~0.6MPa (quick installation type) 304 2
5 respirator Electric heat tracing 5 "

Equipped with sterilization port

304 1
  • controller

Serial Number name Specification and model material quantity notes
1 Yokogawa Recorder from Japan 6 channels / 1
2 Control cabinet 800x430x1850 (height) 304 1
3 controller / 1
4 PLC dedicated power supply UPS power supply / 1