AVEENTICS solenoid valve
Structural point lifting valve
Installation position: ± α=0... 90 °± β=0... 90 °
Certificate of Conformity CE Certification
See table for high operating pressure
The ambient temperature is 0 .. 50 °C
The temperature range of the medium is 0 .. 50 °C
Compressed air interface population G 1/8 1/8 NPT
Compressed air interface outlet G 1/8, 1/8 NPT
Compressed air medium
Particle size max 50 µ m
Oil content in compressed air 1 mg/m ³
Rated flow Qn 120 l/min
AVEENTICS solenoid valve
Control mode analog quantity
Working voltage DC 24V
Voltage deviation DC -20%/+20%
Allowable pulsation of 5%
Power consumption max 300 mA
Protection level IP65
Weight 0.32 kg
Rated flow Qn, when the working pressure is 7 bar, the secondary pressure is 6 bar, and Δ p=0.2 bar
Do not exceed the small control pressure, otherwise it may cause circuit faults and possible valve failures!
The pressure dew point must be at least 15 ° C lower than the ambient and medium temperature, and the allowable temperature is 3 ° C.
The oil content of compressed air must remain constant throughout its entire service life.
Only oils approved by AVEENTICS company can be used. For detailed information, please refer to the document "Technical Information" (obtained from MediaCentre).
Oil free and dry air can be installed in other locations.
The valves of the ED02 series can be locked by a pull rod (see attachment).
Only by installing the plug according to regulations can the protection level be achieved. Please refer to the operating manual for detailed information.
The threads of the compressed air joint are suitable for G1/8 and 1/8 NPTF respectively.