andSEALLike other intermittent analyzers in the series,AQ700We will provide you with high-quality analysis and eliminate the inherent problems caused by analyzers designed for clinical use.SEALContinuously develop software and hardware to meet specific requirements of environmental samples.
Why choose AQ700?
Truly unmanned operation, capable of running overnight
Automatic standard preparation and dilution of samples exceeding the range
Can add samples after running starts
Excellent robotic arm, faster sample preparation process
No carryover or cross contamination
EPA recommended optical inert quartz colorimetric cell
Standard 1cm optical path length, longer optional
Lower detection limit
Real sample blank deduction mode
Automatic tagging
Easy maintenance
Cooling and non cooling reagent positions
Prepare up to 10 working standards for calibration curves
Chemical reaction reaches equilibrium, simulating flow analysis methods with manual and bubble intervals
Ultra low reagent consumption
Each sample can be programmed for testing, reducing analysis time
How does AQ700 work?
The SEAL AQ700 uses four robotic arms, four sample disks, and two stepper motor-driven injectors to work together to extract, distribute, and mix samples and reagents evenly into the reaction well.The sample and reagent react in the reaction trap according to the programmed time.The reaction products will be transferred to a static optical quartz colorimetric cell for detection, and the absorbance of the reactants will be read on a fixed optical platform to ensure better signal-to-noise ratio.The reaction time is programmable, ranging from a few seconds to tens of minutes, to achieve equilibrium in chemical reactions. It simulates manual methods and flow analysis methods with bubble barriers, ensuring lower detection limits and better reproducibility.Another robotic arm is used to transfer the reaction products from the reaction trap to the colorimetric cell for measurement. In this way, the samples are always read at the same position on the detector and in the same colorimetric cell, eliminating errors caused by moving scratches on the colorimetric cell and differences between different colorimetric cells in the direct reading colorimetric system. The color pool itself does not move, so less movement means higher reliability.useinnovationThe probe cleaner can be used to clean the outer wall of the sampling needle when the probe moves up and down, preventing it from contaminating the next liquid.After each absorbance reading, the colorimetric cell is automatically thoroughly cleaned to eliminate carryover or cross contamination.
Measurement method of intermittent analyzer
Widely used for analyzing water, wastewater, soil extracts, etc
Compliant with ISO intermittent chemical analysis methods
ISO 15923-1 Water Quality - Determination of Selection Parameters through Intermittent Analysis Systems. Part 1: Determination of ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate, and silicate using photometry
ISO 15923-2 Water quality - Determination of selected parameters through intermittent analysis systems. Part 2: Determination of Hexavalent Chromium, Fluoride, Total Alkalinity, Total Hardness, Calcium, Magnesium, Iron, Ferrous, Manganese, and Aluminum by Luminescence Method