The PDRP-30T3X AC/DC voltage drop generator complies with the standards of IEC61000-4-11, GB/T17626.11, IEC61000-4-29, and GB/T17626.29. It is a testing instrument used to test the resistance of electrical and electronic products to grid voltage fluctuations. It can provide a common basis for the reliability assessment of the tested equipment when the grid voltage drops or rises instantaneously, and complete the voltage drop, interruption, and voltage change of the electrical equipment through CPU control.

Product Details

Product Introduction

The PDRP-30T3X AC/DC voltage drop generator complies with the standards of IEC61000-4-11, GB/T17626.11, IEC61000-4-29, and GB/T17626.29. It is a testing instrument used to test the resistance of electrical and electronic products to grid voltage fluctuations. It can provide a common basis for the reliability assessment of the tested equipment when the grid voltage drops or rises instantaneously, and complete the voltage drop, interruption, and voltage change of the electrical equipment through CPU control.

Product features

>10.1-inch touch screen

>Accurate voltage output, smooth and even waveform

>Built in environmental temperature and humidity display, time display

>Function *, can meet more testing requirements of customers

>Using imported programmable high-voltage power supply with stable performance

>Built in international standard level parameters, easy to operate

>Built in RJ45 interface, optional measurement and control software for remote control

Technical Specifications


Communication section parameters

meet the standard

IEC61000-4-11 GB/T17626.11

Voltage variation range

0%~120%

duration

0.5-6000.0 cycles or 1-9ms

Switching phase settings

0-359 ° or asynchronous

Repeated voltage changes

frequency

1~60000c

interval

0.5-6000.0 cycle

Decoupling load capacity

U MAX AC three-phase 380V, I MAX AC 30A

working power supply

AC 220V ±10% 50/60Hz

Standard voltage drop

0%, 40%, 70%, 80%

DC section parameters

meet the standard

IEC61000-4-29 GB/T17626.29

Voltage drop variation

The duration of

1ms~60000ms

Repeated voltage changes

frequency

1c~60000c

Interval voltage variation

The duration of

10ms~60000ms

working method

Automatic, internally triggered

Test equipment DC

power supply

DC 360V Imax 30A

General Parameters

display screen

10.1-inch touch screen

language

Switching between Chinese and English

Scope of working power supply

AC 220V ± 10% 50/60Hz

contact method

RJ45

ambient temperature

15 ℃~35 ℃ (operating conditions)

ambient humidity

30% to 60% (operating conditions)

atmospheric pressure

86kPa~106 kPa (operating conditions)

Instrument power

500W

Instrument size

665mm*800mm*1600mm

Instrument weight

200kg

Instrument working status indication

Front panel LED indicator light