ABSD-A4 infrared temperature sensor

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ABSD-A4 infrared temperature sensor, power supply DC24V, measurement range: -20-300 ℃, output signal: 4-20mA | | Widely used in KY coal conveying system ABSD-A4 online infrared thermometer 4-20mA temperature sensor 4-20mA non-contact transmitter.

Product Details

ABSD-A4 infrared temperature sensor

ABSD-A4 infrared temperature sensor

Infrared temperature sensor ABSD-A4, measurement range: -20-300 ℃, output signal: 4-20mA | coal conveying system | KY

principle

Infrared temperature measurement

-Model: ABSD-A4

-Temperature range: -20-300 degC

-Power supply: 24 VDC

-Output: 4-20 mA (1-5 V, 1-10 V, 0-5 V, 0-10 V)

Infrared thermometer

Model: ABSD-A4 infrared thermometer

Temperature range: -20-300 ℃

Power supply: 24V DC

Output: 4-20mA (1-5 V, 1-10 V, 0-5 V)

Temperature measurement range: 0-100 ℃

Temperature measurement accuracy: ± 1% or ± 0.5 ℃

Environmental temperature: 0-60 ℃

Storage temperature: -20-80 ℃

Response time: 50ms

Distance coefficient: 20:1

Power supply: 24VDC

Output voltage: 4-20mA

Size: Φ 18mmX 42mm (L)

Signal output: standard 4-20mA

Online infrared thermometer ABSD-A4 for use in hot forging medium frequency furnace

Installation guide and precautions:

1. The ABSD series metal shell with M18X1 thread can be used for direct installation, and the installation distance should be moderate (within the range of 20:1 coefficient). If the environmental temperature of the measured object is high, a protective sleeve should also be made to avoid affecting the measurement accuracy of the sensor.

2. Power requirements: Attention should be paid to the voltage range and connection polarity of the power supply. Due to the bright background light of the target being measured (especially direct sunlight or strong lights), it can affect the accuracy of the measurement. Use objects to block strong light from direct targets and eliminate background light interference.

3. If the reflection of the measured object affects the temperature measurement deviation of the sensor, the amplification gain of the sensor can be adjusted.