The752G / 722G / 721G Series Spectrophotometeris a reliable single-beam analytical instrument designed for routine laboratory quantitative analysis, industrial inspection, and multi-scenario testing. Three models are available to match different wavelength requirements:752G (UV-Vis, 200–1000nm),722G (Visible, 325–1000nm), and721G (Visible, 340–1000nm). All models adopt aholographic blazed grating monochromatorand a microcomputer measurement system, delivering stable wavelength accuracy, low stray light, and direct concentration reading. With a backlit LCD display, automatic 0%T / 100%T adjustment, and automatic light door technology, the series combines precise measurement with simple, efficient operation for daily lab workflows.
🔍 Core Features:Holographic blazed grating monochromator + imported photocell detector ensuring wavelength accuracy and reading precision; automatic light door technology protects the photoelectric sensor without requiring a black body; halogen tungsten lamp and long-life deuterium lamp (752G) ensure stable light source across UV-Vis range. Supports concentration direct reading, 30 concentration curve storage, and flexible cuvette configurations designed for research, industrial inspection, and production quality control.
| Product Name | 752G / 722G / 721G Series Spectrophotometer |
| Brand / OEM | TAOMSUN(Overseas Partner: METICULAB) |
| Model Options |
752GUV-Vis, 200–1000nm 722GVisible, 325–1000nm 721GVisible, 340–1000nm |
| Optical System | Single beam, holographic blazed grating monochromator |
| Wavelength Range | 752G:200–1000nm 722G:325–1000nm 721G:340–1000nm |
| Spectral Bandwidth | 752G: 4nm | 722G / 721G: 5nm |
| Wavelength Accuracy / Repeatability | ±2nm / ≤1nm |
| Photometric Range | 0–100.0%T | 0–1.999A | 0–1999C |
| Photometric Accuracy | ±0.5%T | ±0.004Abs (0–0.5A) | ±0.008Abs (0.5–1A) |
| Stray Light | 752G: ≤0.3%T | 722G / 721G: ≤0.5%T |
| Light Source | 752G: deuterium lamp + halogen tungsten lamp | 722G / 721G: halogen tungsten lamp |
| Detector | Imported photocell (silicon photodiode) |
| Display | Backlit LCD, clear readout |
| Measurement System | Microcomputer measurement system, automatic 0%T / 100%T adjustment |
| Concentration Measurement | Direct concentration factor setting and direct concentration reading |
| Light Door Technology | Automatic light door technology (no black body required, protects photoelectric sensor) |
| Sample Compartment | Wide compartment, accommodates 5–100mm cuvettes |
| Standard Accessory | 1cm glass cuvette × 4, 5cm cuvette holder, power cord, fuse, manual |
| Optional Accessories | Thermal printer / spectral analysis software / other cuvette holder specifications / quartz cuvettes |
| Power | 752G: 130W | 722G / 721G: 50W |
| Gross Weight | 752G: 16kg | 722G / 721G: 14kg |
| Quality System | ISO 9001· Precision Optical Manufacturing |
Q: What is the difference between the 752G, 722G, and 721G?
A: The main difference is wavelength range. 752G is UV-Vis (200–1000nm), 722G is Visible (325–1000nm), and 721G is Visible (340–1000nm). Choose 752G if you need UV measurements; choose 722G or 721G for visible-light-only applications.
Q: What are the wavelength accuracy and repeatability?
A: Wavelength accuracy is ±2nm, and repeatability is ≤1nm across all three models.
Q: What is the photometric range and accuracy?
A: Photometric range is 0–100.0%T / 0–1.999A / 0–1999C, with accuracy of ±0.5%T, ±0.004Abs (0–0.5A), ±0.008Abs (0.5–1A).
Q: Does it support direct concentration reading?
A: Yes. Concentration factor can be set directly, and readings are displayed without additional calculation.
Q: What is the function of the automatic light door technology?
A: The automatic light door closes the optical path when not measuring, protecting the photoelectric sensor without requiring a black body, extending component lifespan and reducing maintenance costs.
Q: Can it accommodate other cuvette specifications?
A: Yes. The sample compartment accommodates 5–100mm cuvettes. The standard 1cm cuvette holder can be replaced with optional specifications.
Q: Is it suitable for export?
A: Yes. Export wooden case packaging, English manual, and 110V/220V customization are available. EXW / FOB / CIF terms are supported.
Q: What is the warranty?
A: One-year whole-machine warranty. Light sources and other consumable parts can be consulted for replacement.
TAOMSUNis a laboratory analytical instrument supplier integrating R&D, production, and sales. Our production processes are certified under the ISO 9001 quality management system, with product lines covering spectrophotometers, spectral analysis instruments, and supporting consumables. Core optical systems are manufactured and assembled with precision processes to ensure wavelength accuracy and data reliability for every instrument. Products are widely used in chemical, pharmaceutical, environmental, food, and university research fields.🌏 Overseas technical support provided by METICULAB, Korea.
All TAOMSUN products are manufactured under the ISO 9001 quality management system. Specifications are standard configurations; customized configurations may vary.