A 60KW air-cooled chiller, as the name suggests, uses a cooling fan to dissipate heat from the chiller without the need for a cooling tower. This eliminates the installation of cooling water pipelines, cooling towers, and other accessories, as well as the maintenance costs of the cooling tower in the later stage, saving labor costs in the later stage.
A 60KW air-cooled chiller, as the name suggests, uses a cooling fan to dissipate heat from the chiller without the need for a cooling tower. This eliminates the installation of cooling water pipelines, cooling towers, and other accessories, as well as the maintenance costs of the cooling tower in the later stage, saving labor costs in the later stage.
| |
SJ-20AD |
| refrigeration power |
Kcal / KW |
51600 / 20 |
| power supply |
V |
3∮ 380~380V- 50HZ(Can be customized) |
| operating current |
A |
36 |
| refrigerant |
Kind |
R407C, R404A, R134A |
| FILLING QUANTIT(kg) |
11 |
| compressor power |
KW |
8.1*2 |
| Number of compressors |
|
2 |
| cooling air volume |
m3/h |
20000 |
| water pump |
KW |
1.5 |
| chilled water volume |
m3/hr |
11 |
| Standard pipe diameter |
MM |
60 |
| Design dimensions |
L(mm) |
1955 |
| W(mm) |
940 |
| H(mm) |
1600 |
| weight |
kg |
590 |
For more model parameters, please click to enter
A 60KW air-cooled chiller with two 10HP scroll compressors inside. The company defaults to using Japanese Panasonic brand compressors (which can also be customized according to the brand provided by the user), with a cooling capacity of 30KW per compressor.
The benefits of using two compressors:
1. Energy saving: Under load conditions below 50%, the unit only operates one compressor, but can fully utilize the heat exchange area of the entire evaporator and radiator, which can greatly improve cooling capacity and maximize energy efficiency.
2. Starting current: The compressors start one by one, with low starting current, minimal impact on the power grid, and stable power grid.
3. Maintenance and repair: If a single compressor experiences refrigerant leakage or aging of spare parts, it can only be shut down for maintenance. If two compressors are used, when one compressor fails, the other compressor can cool without stopping production, and maintenance and use do not conflict.
It is recommended to place the air-cooled chiller in a relatively ventilated location around it for easy heat dissipation. If placed indoors, a guide duct can be used to discharge hot air outside (it is recommended that the ambient temperature be below 40 ℃). Alternatively, an ultra quiet fan can be customized according to user requirements. The noise of the indoor fan will not affect nearby operators.
Schematic diagram of 60KW air-cooled chiller
Q: Can this 60KW air-cooled chiller be customized to the size I need?
Answer: Absolutely, our company can customize according to the length, width, and height provided by the user.