33101-SL-7-2R-B5/SIL certified pneumatic valve from Rotex India

SIL certification (Safety Integrity Level) is a functional safety certification system used to evaluate the reliability level of safety related systems in specific risk scenarios, ensuring that equipment or systems can effectively perform safety functions in the event of danger, reducing the risk of personnel injury, environmental damage, or property damage.
Risk based approach
SIL certification follows the IEC 61508 standard (corresponding to GB/T 20438 in China), and achieves risk reduction goals step by step by quantifying the system's "probability of failure on demand (PFD)" or "risk reduction factor (RRF)". For example, the PFD corresponding to SIL3 istoThe probability of failure is between 0.1% and 0.01%.
Multi domain standard collaboration
IEC 61508Functional safety basic standards for electrical/electronic/programmable electronic safety related systems, covering the entire lifecycle of the system (design, development, testing, maintenance).
IEC 61511Standardize the design, implementation, and maintenance requirements for Safety Instrumented Systems (SIS) in process industries such as chemical and petrochemical industries.
ISO 13849-1Standards in the field of mechanical safety, providing quantitative design methods (such as system safety level PLr, mean time to failure MTTFd).
IEC 62061Mechanical and electrical safety standards, complementary to ISO 13849-1, applicable to the field of electrical systems.
ISO 26262The automotive functional safety standard, derived from IEC 61508, defines the safety requirements for automotive electronic/electrical systems.
SIL certification is divided intoSIL1、SIL2、SIL3、SIL4Four levels, with SIL4 as the highest level, require the system to maintain high reliability and low failure probability under harsh conditions. The specific level requirements are as follows:
| level | Failure probability range | Typical application scenarios | Technical Requirements |
|---|---|---|---|
| SIL1 | to | Ordinary industrial equipment (such as low-risk machinery control) | Single layer protection, basic hardware reliability design. |
| SIL2 | to | Petrochemical and power industries (such as tank pressure control) | Redundant design, fault diagnosis coverage rate ≥ 60%. |
| SIL3 | to | Chemical plants, rail transit (such as emergency braking systems) | Double redundancy design, high coverage fault diagnosis (≥ 90%), strict requirements for environmental testing and EMC testing. |
| SIL4 | ≤ | Nuclear power, aviation control systems (such as reactor protection) | Multiple redundancies (such as triple module redundancy TMR), real-time self checking, hardware fault margin ≥ 2, safety failure score ≥ 99.99%. |