2025 New Asphalt Testing Instrument Asphalt Standard Viscosity Tester

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The new asphalt testing instrument for 2025, the asphalt standard viscosity tester, is designed and manufactured in accordance with the requirements specified in T0621-2011 "Asphalt Standard Viscosity Test (Road Asphalt Standard Viscometer Method)" of the industry standard JTG E20-2025 "Test Procedures for Asphalt and Asphalt Mixtures in Highway Engineering" of the People's Republic of China. It is suitable for measuring the viscosity of liquid petroleum asphalt, coal tar pitch, emulsified asphalt and other flow states according to the methods specified in T0621-2025 standard.
Product Details

New asphalt testing instrument by 2025Asphalt standard viscosity tester


1、 Product Introduction:

This instrument is designed in accordance with the industry standards of the People's Republic of ChinaJTG E20-2025In the "Test Regulations for Asphalt and Asphalt Mixtures in Highway Engineering"T0621-2011Designed and manufactured in accordance with the requirements specified in the "Asphalt Standard Viscosity Test (Road Asphalt Standard Viscometer Method)", applicable toT0621-2025The method specified in the standard is used to determine the viscosity of liquid petroleum asphalt, coal tar pitch, emulsified asphalt and other flowing states.

2、 Main technical parameters and indicators:

1Temperature control range: room temperature~90℃;

2Temperature control accuracy:±0.1℃;

3Timing resolution:0.1s, Maximum timing value 999.9s;

4Heating power500W;

5Flow hole diameter:φ2mm±0.025mmφ3mm±0.025mm; φ4mm±0.025mm; φ5mm±0.025mm; φ10mm±0.025mm

6Ball plug specification: A: Ball diameter 12.7mm ± 0.05mm; Mark height 92mm ± 0.25mm;

B: Ball diameter 6.35mm ± 0.05mm; Mark height 90.3mm ± 0.25mm;

C:Ball diameter3.5Mm ± 0.05mm; mark height 900mm±0.25mm;

7Sample tube: inner diameter40mm depth 105mm

8Sink: Inner diameter160mm depth 118mm

9Power supply voltageAC(220±10%)V 50HZ。

3、 Instrument operation:

1Fill the circulating water tank with water.

2Turn on the power switchtemperature controlSwitch, at this point, the water will circulate and heat up, causing the water level to drop. It is necessary to continue adding water to the sink until the water hole above flows outwards.

3Set the instrument to the desired temperature value. The routine test is60℃。

4、 Experimental steps:

1Heat the sample to a temperature higher than the test temperatureInject into the sample tube at 2-3 ℃ (if the test temperature is lower than room temperature, the sample needs to be cooled to 2-3 ℃ lower than the test temperature), and the quantity should be based on the mark on the rod when the liquid level reaches the vertical position of the ball stopper rod.

2The sample should be kept at least at the test temperature in the water tank30min, When the temperature of the measured sample is within ± 0.1 ℃ of the test temperature, adjust the liquid level of the sample to the mark on the ball rod, and then continue to maintain it for 1-3 minutes

3Remove the evaporating dish under the flow hole and place it in a receiving bottle or graduated cylinder with its center facing the flow hole. The receiving bottle or graduated cylinder can be pre filled with soapy water or mineral oil20ml, To facilitate washing and accurate reading.

4Lift the ball stopper and hang it on the edge of the sample tube with a marker, waiting for the sample to flow into the receiving bottle or measuring cylinderPress the stopwatch when 25ml (graduated cylinder scale 50ml) is reached, and stop the stopwatch when 75ml (graduated cylinder scale 100ml) of the sample flows out.

5Record the outflow of the sampleThe time taken for 50ml, measured in seconds, is the viscosity of the sample.

6Report: The same sample shall be tested in parallel at least twice, and the difference between the two measurements shall not exceed the average valueAt 4%, take the integer of its average as the experimental result.

7Precision or allowable deviation: The allowable deviation for repeatability testing is the average value4%.

5、 Attention:

1Open box inspection: Check if the instrument has malfunctioned due to transportation.

2Check if there are any missing parts on the packing list, promptly notify our sales team, and contact us.

3Remember to add water to the sink before turning on the power to prevent damage to the heating tube caused by dry burning.

6、 Packing list:

1host 1 unit

2Sample tube:1 piece

3Flow hole:5only

4Ball stopper: 3only

5power cord:1 piece

7Panel layout:

8Operation Manual

1. Temperature control switch: turn on/off temperature control.

2. Loop switch: Turn on/off the loop.

3. Lighting switch: turn on/off lighting.

4. Timer switch: Turn on/off the timer function.

5. Settings: Set internal parameters. (Usually not adjusted)

New asphalt testing instrument by 2025Asphalt standard viscosity tester