2000 Intelligent Radon Meter (Alpha Spectrometer) Complete Equipment @ Description Test Scope: The instrument can be used for indoor radiation environment radon level monitoring and pollution control in civil construction projects. It is also suitable for investigating and evaluating radon concentration in soil at civil construction sites. It is applicable for engineering geological exploration, mineral resource exploration, environmental radon concentration monitoring in nuclear industry departments, earthquake and geological disaster prediction monitoring, determining geological structures in geological surveys, water quality evaluation, and other work such as radon concentration radiation detection.

Product Details

APY-2000 Intelligent Radon Meter (Alpha Spectrometer)


(1)2000 Intelligent Radon Meter (Alpha Spectrometer) Complete Equipment@Explanation of standard specifications:

GB 50325-2020 "Standard for Indoor Environmental Pollution Control of Civil Building Engineering"

GB/T 14582-93 "Standard Measurement Method for Radon in Environmental Air"

◆ T/CECS 569-2019 "Standard for Radon Detection in Indoor Air of Buildings"


II)2000 Intelligent Radon Meter (Alpha Spectrometer) Complete Equipment@ExplanationTest scope:

The instrument can be used for monitoring indoor radon levels and pollution control in civil construction projects. The investigation and evaluation of radon concentration in soil at civil construction sites are suitable for engineering geological exploration, mineral resource exploration, environmental radon concentration monitoring by relevant departments in the nuclear industry, earthquake and geological disaster prediction monitoring, radon concentration radiation detection in geological surveys to determine geological structures, water quality evaluation, and other work.



equipment image


2000智能测氡仪(α谱仪)全套设备

3)Device configuration:

*Capable of measuring soil radon, air radon, water radon concentration, and radon release rate with multiple functions;

*The equipment is designed using the active pump suction static collection energy spectrum analysis method;

*The alpha energy spectrum has good resolution, high sensitivity, and real-time display of spectra;

*The system control circuit and digital processing circuit used;

*The instrument adopts modular design, touch keyboard operation, user-friendly human-machine interface, and simple operation;

*Recovery: Rapid recovery in a short period of time after exposure to high levels of radon;

*5-inch high-definition true color digital touch screen with output resolution of 800 * 480, easy to operate;

*It can complete quantitative testing of radon concentration and thorium gas concentration in one go, and the measurement data is automatically saved;

*The instrument has temperature and humidity correction functions, resulting in more accurate measurement data;

*Equipped with a micro printer, it can print measurement data on site;

*Small size, light weight, easy to carry;


IIIWorking parameters:

##Using GM30 gold silicon surface barrier semiconductor detector, real-time display of alpha spectral lines;

##Measurement objects: Rn-222 (radon), Rn-220 (thorium);

##Radon progeny electrostatic high voltage collection chamber: 1.0L, sampling pump flow rate of about 1L/min;

##Adopting a low-power 512 channel multi-channel pulse analyzer;

##Simultaneous measurement of temperature, humidity, and air pressure, with automatic correction of temperature and humidity;

##Measurement time: 1-60000 minutes optional;

##Background count: ≤ 0.03count/min;

##Detection sensitivity: ≥ 0.013 cpm/[Bq · m-3] (0.48 cpm/[pCi/L]);

##Detection limit:<2Bq/m3;

##Measurement range: Air radon: (2~100000) Bq/m ³

#Soil radon: (300-1000000) Bq/m ³

#Precipitation rate: (0.001-33.000) Bq/[m2s]

#Radon in water: (0.002-1000) Bq/L (optional)

##Measurement uncertainty: ≤ 20% (K=2) (radon chamber concentration ≥ 2000Bq/m ³, temperature 25 ° C: ≤ 10%);

##Storage capacity: 100000 sets of measurement results and spectral line data;

##Power supply:+12V (rechargeable battery);

##Environmental conditions: -10 ℃ -+50 ℃; Relative humidity: ≤ 95% (non condensing);

#Volume: 35cm × 28cm × 18cm Weight: 5Kg.


4Basic Configuration

4.1 Configuration Table

serial numberAccessory namequantityBasic Configurationoptional

1Radon detector1 unit√

2Special charger for radon detector1 piece√

3Instrument User Manual1 copy√

4Certificate of Conformity1 copy√

5Accessory packaging box1 piece√

6Soil radon gas extraction device1 piece√

7Soil drilling steel drill1 piece√

8dry powder2 bottles√

9Drier nozzle plug (spare)2 of them√

10Drying machine (including air nozzle plug)1 piece√

11Intermediate dryer (including air nozzle plug)1 piece√

12Accessories for measuring soil surface precipitation rate1 piece√

13Accessories for measuring radon release rate on material surfaces1 piece√

14Water radon measurement accessories1 piece√

15printer1 piece√

16printing paper4 rolls√

17Instrument calibration certificate1 copy√

18GPS、 Beidou module1 set√

19Data remote module1 set√

20Dedicated power bank1 set√

Principle of Radon Meter, Radon Meter Operation Video, Radon Meter Usage Instructions, Radon Meter User Manual, Radon Meter Manufacturer, Radon Meter Usage Instructions

2000智能测氡仪(α谱仪)全套设备

2000智能测氡仪(α谱仪)全套设备


2000智能测氡仪(α谱仪)全套设备