2-pentenenitrile rapid detection tube detector toxic tube test tube
It adopts the advanced management philosophy and system of Japan's Gastec Cor cooperation, and accepts the entrustment of Japan's Gastec Company to take full charge of the sales business of its original products in Chinese Mainland. Beijing Kesite Gas Technology Co., Ltd. provides gas generators, permeation tubes, gas samplers, gas detection tubes and other products and services to a wide range of domestic customers, including Tsinghua University Yangtze River Delta Research Institute, Philips Research Institute, Coca Cola Company, Agilent, Centers for Disease Control and Prevention (CDC), environmental monitoring agencies, research institutions, etc. It has gained recognition from customers and established good cooperation.
It adopts the advanced management philosophy and system of Japan's Gastec Cor cooperation, and accepts the entrustment of Japan's Gastec Company to take full charge of the sales business of its original products in Chinese Mainland. Beijing Kesite Gas Technology Co., Ltd. provides gas generators, permeation tubes, gas samplers, gas detection tubes and other products and services to a wide range of domestic customers, including Tsinghua University Yangtze River Delta Research Institute, Philips Research Institute, Coca Cola Company, Agilent, Centers for Disease Control and Prevention (CDC), environmental monitoring agencies, research institutions, etc. It has gained recognition from customers and established good cooperation.
The 2-pentenenitrile detection tube is a sealed, slender glass tube that presents a specific color due to being filled with specific reagents and coloring agents. When a gas sample containing 2-pentenenitrile enters the detection tube, a chemical change occurs, causing a change in color. The scale corresponding to the boundary of color change observation is the concentration of 2-pentenenitrile in the tested sample.

| Testing Scope | 0.5-6ppm | 6-15ppm | |
| Extraction frequency (volume) | 4(400ml) | 2(200ml) | |
| correction factor | 1 | 2.5 | |
| pumping time | 8 minutes | 4 minutes |
Detection limit: 0.1ppm (4 extractions)
Color Change: Yellow Red
Temperature and humidity correction: Temperature correction is required
Relative standard deviation: 10% (0.5-2ppm), 5% (2-6ppm)
Validity period: 3 years
reaction principle:
Preprocessing tube:CH3CH2CH:CHCN +Cr6++H2SO4HCN
Testing tube:2HCN+HgCl22HCl
HCl+indicator chloride
2-pentenenitrile rapid detection tube detector toxic tube test tube