Zhongkedi Listening Wheel Electrode Atomic Emission Spectrometer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

DITEE OA800H Oil Spectral Analyzer is a high-performance rotary electrode atomic emission spectrometer designed for analyzing the elemental content of lubricating oil, hydraulic oil, fuel, coolant, grease, and industrial circulating water. Widely used in fields such as military, aviation, shipping, nuclear power, wind power, electricity, petrochemicals, mining, rail transit, engineering machinery, university research, and oil testing. By detecting the elemental content of worn metals, pollutants, and additives, OA800H can accurately determine the wear, sealing, overheating, and other faults of large equipment, assisting in the status monitoring, fault diagnosis, and early warning of key equipment.

Product Details


DITEEOA800H Oil Spectral AnalyzerIt is a high-performance rotary electrode atomic emission spectrometer designed for analyzing the elemental content of lubricating oil, hydraulic oil, fuel, coolant, grease, and industrial circulating water. Widely used in fields such as military, aviation, shipping, nuclear power, wind power, electricity, petrochemicals, mining, rail transit, engineering machinery, university research, and oil testing. By detecting the elemental content of worn metals, pollutants, and additives, OA800H can accurately determine the wear, sealing, overheating, and other faults of large equipment, assisting in the status monitoring, fault diagnosis, and early warning of key equipment.

DITEEOA800H Oil Spectral AnalyzerWidely used in fields such as military, aviation, shipping, nuclear power, wind power, electricity, petrochemicals, mining, rail transportation, engineering machinery, university research, and oil testing institutions for oil quality monitoring, equipment wear monitoring, and fault diagnosis analysis, it is a standard analytical method in the field of oil analysis.

The DITEEOA800H oil spectrometer mainly includes an excitation system, an optical system, and a readout system

1. The arc or spark generated by the discharge of the excitation system directly acts on the tested oil sample, exciting the outer electrons of the element and producing characteristic spectral lines. The graphite disk electrode continuously rotates to bring oil between the electrodes. There is a huge potential difference between the graphite disk electrode and the rod electrode. When the potential difference between the electrodes reaches a discharge state, high voltage discharge occurs at the gap between the electrodes, generating high-temperature arcs or sparks, providing instantaneous high temperature, causing the oil sample on the disk electrode to burn, vaporize and plasma. The discharge gap generates instantaneous high temperature, which can fully excite various elements in the oil sample and produce stable emission spectra. The spectral signal is flexibly introduced into the Roland circular spectroscopy system through ultraviolet optical fibers.

2. The optical system uses a grating placed on a Roland circle to collect and split the characteristic spectral lines of the excited elements (the larger the focal length and the more grating lines, the higher the resolution and the better the splitting effect); The detector receives and performs photoelectric conversion on each characteristic spectral line.

3. The readout system periodically reads the charge on the detector and converts it into a digital signal, which is the intensity of the characteristic spectral lines of each element. The intensity is proportional to the element concentration. The readout system compares the standard curve, analyzes, processes, and outputs the data to obtain the content of each element.

DITEEOA800H Oil Spectrometer Meets Standards

ASTMD6595 "Standard Test Method for Determination of Wear Metals and Contaminants in Lubricating Oil or Hydraulic Fluid by Rotary Disc Electrode Atomic Emission Spectroscopy"

ASTMD6728 "Standard Test Method for Determining Pollutants in Gas Turbine and Diesel Engine Fuels by Rotary Disc Electrode Atomic Emission Spectroscopy"

NB/SH/T0865 National Energy Administration Standard "Determination of Wear Metals and Pollutant Elements in Lubricating Oil in Use - Rotating Disc Electrode Atomic Emission Spectroscopy Method"

SN/T1652 General Administration of Inspection and Quarantine Import and Export Industry Standard "Detection Method for Pollutants in Fuel Oil of Gas Turbine and Diesel Engine for Import and Export - Rotating Disk Electrode Atomic Emission Spectroscopy"

DL/T1550 National Energy Administration Power Industry Standard "Determination of Copper and Iron Content in Mineral Insulated Oil - Rotating Disc Electrode Emission Spectroscopy Method"

Product Features | Product Features

Oil spectrometer is an oil monitoring equipment widely recognized by various customers, industrial customers, and commercial oil laboratories through long-term application practice. It is also a reliable and effective oil monitoring technology. It can achieve status monitoring of key oil equipment and can also be used for quality control of oil products.

● Suitable for simultaneous multi-element determination of various metal elements such as wear metals, pollutants, and additives in oil materials

The standard configuration can simultaneously measure 24 analytical elements (aluminum, barium, boron, calcium, chromium, copper, iron, lead, magnesium, molybdenum, nickel, phosphorus, potassium, silicon, silver, sodium, tin, titanium, vanadium, zinc, manganese, cadmium, lithium antimony). The detection channels can be flexibly increased according to different needs, and adding elements does not require hardware changes

● Built in working curve

No need for sample pre-treatment, direct injection, single test for about 40 seconds, adjustable time, measurement once to obtain results

Low usage cost, with only standard graphite disk electrodes, rod electrodes, and sample cups as consumables

● Disk electrode material: made of graphite (spectral purity), non ceramic material

● Adopting concentrated optical fiber introduction to ensure instrument resolution

The light chamber is equipped with a sealed and isolated heat exchanger, effectively blocking the invasion of dust, water mist, and oil mist

The equipment has an exhaust structure to prevent cross contamination

No need for xenon gas, no need for cooling water

● Integrated fully enclosed frame structure design, resistant to impact and deformation; Multi panel design with reasonable internal partition intervals

Analysis Scope

The oil working curve is drawn by Zhongke Diding Company using international standard oil products (the linear range of the detector is greater than the following working curve range). For special elements and analysis scope proposed by users, standard oil can be provided by users, and Zhongke Diding Company can expand it for free.

serial number element name Element symbol Analysis range (ppm)
1 aluminium Al 0-1000
2 barium Ba 0-6000
3 boron B 0-1000
4 cadmium Cd 0-1000
5 calcium Ca 0-6000
6 chromium Cr 0-1000
7 copper Cu 0-1000
8 Iron Fe 0-1000
9 lead Pb 0-1000
10 magnesium Mg 0-6000
11 manganese Mn 0-1000
12 molybdenum Mo 0-1000
13 nickel Ni 0-1000
14 phosphorus P 0-6000
15 silicon Si 0-1000
16 Silver Ag 0-1000
17 sodium Na 0-6000
18 tin Sn 0-1000
19 Titanium Ti 0-1000
20 vanadium V 0-1000
21 zinc Zn 0-6000
22 potassium K 0-1000
23 lithium Li 0-1000
24 antimony Sb 0-1000

Technical Parameters

optical system


● Optical system: Pashen Runge Paschen Runge Roland circular optical structure focal length: 500mm

High performance holographic concave diffraction grating with grating lines of 2700L/mm

Optical resolution: 0.006nm

Spectral range: 190-900nm

Dual cell: Short wave cell spectral line range: 190nm~470nm; Long wave cell spectral line range: 470nm~900nm

The host and the light room have bidirectional independent constant temperature control, with a temperature control accuracy of 40 ℃± 1 ° C and adjustable temperature

detector

● Aggregation fiber optic signal transmission double-layer multi CCD spectroscopy system

Multiple CCD linear arrays arranged in a circular cross shape to achieve continuous and simultaneous detection across the entire frequency band, making it easy to expand other elements in the later stage

High performance CCD detector, each CCD with 3648 pixels

UV band spectral enhancement detection technology enhances the intensity of UV band light and extends its lifespan

Excitation light source

Bidirectional excitation high-performance spark light source, ignition voltage 14000V, digital discharge parameter setting, digital pulse generator, digital offline pulse control

● Dual phase zero crossing signal detection technology to avoid high-voltage spark electromagnetic compatibility interference and improve voltage stability

Excitation room

The rod-shaped electrode holder of the automatic adjustment electrode spacing device ensures that the height of the electrode spacing is consistent during each measurement

The excitation room is equipped with a visual window, which allows for a clear understanding of the entire excitation process

● Complete safety monitoring and protection functions, including excitation chamber door safety lock, sample cup, disk electrode, rod electrode, spark gap sensing and monitoring device (laser light source automatic positioning), with safety alarm and automatic shutdown functions to ensure user safety

A semi transparent cut-off plate that prevents oil splashing pollution and filters stray light

Aluminum fire extinguishing device to prevent the burning of volatile samples and the generation of large amounts of open flames

computer system

● Software/Operating System: Instrument control and data management software based on the Windows platform

● Control computer external connection

Power and environmental requirements

Power supply: 220V ± 10%, 50/60Hz, AC power supply, built-in voltage regulator, no need for dedicated grounding device

Power consumption: ≤ 1kw

● Fuse current: 16A

● Operating temperature range: -40~50 ° C

Maximum allowable temperature change: ± 5 ° C/hour

Working humidity: 0~90%, no condensation

● Working altitude: ≤ 7000 meters

Dimensions and Weight

● Size: 800mm (length) X420mm (width) X600mm (height)

Weight: 70kg