Constant pressure water supply vector frequency converterApplicable industries:
Metal processing machinery, plastic machinery, printing, dyeing, papermaking, municipal engineering, chemical fiber, cement, ceramics, tension control, lifting machinery, elevator control, rapid injection molding, various machine tools, petrochemical, metallurgical and other industries.

Constant pressure water supply vector frequency converterPerformance advantages:
1. The control modes are diverse and flexible, covering sensorless vector control, closed-loop vector control, and optimized V/F control. It has two methods: speed control and torque control. Suitable for various application requirements.
2. Adopting excellent magnetic flux vector control algorithm, the frequency converter has high control accuracy, fast speed response, and low-frequency characteristics.
3. High speed control accuracy, ± 0.5% rated synchronous speed (without PG vector control); ± 0.1% rated synchronous speed (with PG vector control); ± 1% rated synchronous speed (V/F control).
4. Self learning function, speed tracking, more precise and flexible control.
5. Compact structure, high power density, easy installation, and high cost-effectiveness.
6. Rich peripheral expansion functions enable bus expansion, terminal, relay, and analog expansion.
7. Supports CAN Open, CAN Link, Profibus, Modubus, and free protocols, making bus control effortless.
8. Supports local LED single display, dual display keyboard, local LCD keyboard, and remote LCD keyboard.
9. Intelligent protection and detection, with input phase loss protection function, output phase loss protection, output phase to phase short circuit protection, and output to ground protection function.
Power range: single-phase 220V: 0.4KW~3.7KW
Three phase 380V: 0.75KW~75KW
Menu:
project |
Project Description |
|||
input |
Rated voltage, frequency |
Single phase 220V level: Single phase 220V, 50Hz/60Hz; Three phase 380V level: Three phase 380V, 50Hz/60Hz |
||
Allowable voltage fluctuation range |
Single phase 220V level: 200-260V; three-phase 380V level: 320-460V |
|||
output |
voltage |
0~380V |
||
frequency |
0~600Hz |
|||
overload capacity |
G-type: 150% rated current for 1 minute; P-type: 120% rated current for 1 minute. |
|||
control performance |
Control method |
No PG vector control, with PG vector control, open-loop V/F control, no PG torque control, with PG torque control |
||
Speed control accuracy |
± 0.5% rated synchronous speed (without PG vector control); |
|||
± 0.1% rated synchronous speed (with PG vector control); | ||||
± 1% rated synchronous speed (V/F control); | ||||
speed regulation range |
1: 2000 (with PG vector control); |
|||
1: 100 (without PG vector control); | ||||
1: 50 (V/F control); | ||||
Starting torque |
1.0Hz: 150% rated torque (V/F control); |
|||
0.5Hz: 150% rated torque (without PG vector control); | ||||
0Hz: 180% rated torque (with PG vector control); | ||||
Speed fluctuation |
± 0.3% rated synchronous speed (without PG vector control); |
|||
± 0.1% rated synchronous speed (with PG vector control); | ||||
Torque control accuracy |
± 10% rated torque (without PG vector control, without PG torque control); |
|||
± 5% rated torque (with PG vector control and PG torque control). | ||||
Torque response |
≤ 20ms (without PG vector control); |
|||
≤ 10ms (with PG vector control); | ||||
Frequency accuracy |
Digital setting: high frequency x ± 0.01%; Simulation setting: High frequency x ± 0.5% |
|||
frequency resolution |
Simulation setting |
High frequency 0.1% |
||
Numerical setting accuracy |
0.01Hz |
|||
External pulse |
High frequency 0.1% |
|||
Torque increase |
Automatic torque boost; Manual torque increased by 0.1-12.0% |
|||
V/F curve (voltage frequency characteristics) |
The rated frequency can be set arbitrarily between 5 and 650Hz, and five types of curves can be selected: constant torque, decreasing torque 1, decreasing torque 2, decreasing torque 3, and custom V/F |
|||
Acceleration and deceleration curve |
Two methods: linear acceleration and deceleration and S-shaped acceleration and deceleration; 15 types of acceleration and deceleration times, with optional time units (0.01s, 0.1s, 1s), lasting for 1000 minutes |
|||
braking |
Energy consumption braking |
The EN600 series three-phase power range of 15KW and below has a built-in braking unit, and only a braking resistor needs to be added between (+) and PB; 18.5KW and above power range |
||
Optional built-in braking unit, simply add a braking resistor between (+) and PB, or connect an external braking unit between (+) and (-). | ||||
The EN500 series can be equipped with an external brake unit between (+) and (-). | ||||
DC braking |
Start and stop actions can be selected separately, with an action frequency of 0-15Hz, an action current of 0-15Hz, and an action time of 0-300s |
|||
jog |
Jogging frequency range: 0Hz to upper limit frequency; Jogging acceleration and deceleration time can be set from 0.1 to 6000.0 seconds |
|||
Multi speed operation |
Multiple speed operation can be achieved through built-in PLC or control terminals, up to 15 segments, with each segment corresponding to a separate acceleration and deceleration time. The built-in PLC supports power-off saving |
|||
Built in PID control |
Can easily form a closed-loop control system |
|||
Automatic energy-saving operation |
According to the load situation, automatically optimize the V/F curve to achieve energy-saving operation |
|||
Automatic Voltage Regulation (AVR) |
When the voltage of the power grid changes, it can automatically maintain a constant output voltage |
|||
auto current limiting |
Automatically limit the current during operation to prevent frequent overcurrent faults and tripping |
|||
Carrier modulation |
Automatically adjust the carrier based on load characteristics |
|||
Speed tracking restart |
Realize smooth starting of rotating motors without impact |
|||
Operation function |
Run the command on the given channel |
The operation keyboard, control terminal, and communication settings can be switched in multiple ways |
||
Operating frequency given channel |
Given the main and auxiliary settings, achieve one main adjustment and one fine adjustment control. Digital Given, Analog Given, Pulse Given, Pulse Width Given, Communication Given |
|||
Fixed class can be switched at any time through various methods | ||||
Binding function |
The command channel and frequency given channel can be freely bundled and switched synchronously |
|||
input |
Digital input channel |
8 universal digital input channels, with a high frequency of 1KHz, of which 1 can be used as a pulse input channel. The large input is 50KHz and can be expanded to 14 channels |
||
output |
Analog input channel |
2 analog input channels, among which AI1 can choose 4-20mA or 0-10V output, AI2 channel is differential input, 4-20mA or -10~10V output |
||
feature |
Optional input, expandable to 4 analog inputs |
|||
| |
Pulse output channel |
Pulse square wave signal output ranging from 0.1 to 20KHz, capable of outputting physical quantities such as set frequency and output frequency |
||
| |
Analog output channel |
Two analog signal outputs, with AO1 channel selectable from 4-20mA or 0-10V, and AO2 channel selectable from 4-20mA or 0-10V to achieve set frequency |
||
| |
The output of physical quantities such as rate and output frequency can be extended to 4 analog outputs |
|||
Featured Features |
Fast current limiting |
Greatly limit the overcurrent of the frequency converter and ensure more reliable operation |
||
Single pulse control |
Suitable for situations where one click control of the frequency converter is required, press start once, press stop again, press start again, and repeat this process. this |
|||
The usage is simple, reliable, and not easy to operate incorrectly | ||||
Fixed length control |
Can achieve fixed length control |
|||
timing control |
Timer control function: Set time range from 0.1Min to 6500.0Min |
|||
Virtual terminal |
Five sets of virtual input and output IO, which can achieve simple logic control |
|||
operate the keyboard |
LED display |
Can display various parameters such as set frequency, output frequency, output voltage, output current, etc |
||
Key lock |
Implement partial or complete locking of keys |
|||
protection function |
Short circuit detection of power on motor, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection |
|||
Underload protection, relay closing protection, terminal protection, instantaneous power outage without stopping, etc | ||||
environment |
Usage location |
Indoor, not exposed to direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, dripping or salt, etc |
||
altitude |
Below 1000 meters. (When the height is higher than 1000 meters, the rated current needs to be reduced by about 10% for each additional 1000 meters of height.) |
|||
ambient temperature |
-10 ℃~+40 ℃ (If the ambient temperature is between 40 ℃~50 ℃, please reduce the rating or enhance the heat dissipation) |
|||
ambient humidity |
Less than 95% RH, no condensation of water droplets |
|||
vibration |
Less than 5.9 meters per second ² (0.6g) |
|||
Storage temperature |
-40℃~+70℃ |
|||
structure |
Protection level |
IP20 |
||
cooling method |
forced air cooling |
|||
Installation method |
wall-mounted |
|||