- Phone
-
Address
A11 Floor, Boke Building, No. 9 Xiyuan Road, Xihu District, Hangzhou City, Zhejiang Province
Hangzhou Shuce Technology Co., Ltd
A11 Floor, Boke Building, No. 9 Xiyuan Road, Xihu District, Hangzhou City, Zhejiang Province
Wireless temperature and pressure verification probeIt is mainly used for environmental pressure verification of equipment, such as pressure vessels, internal and external pressure difference verification of products, and other environmental verifications. During the verification process, there is no need to pull a line, and the wireless pressure verification probe (absolute pressure range: 0-680kpa) can be directly placed in the tested environment. The verification data will be completely recorded inside the probe, and even if the battery is exhausted, the recorded data will not be lost, ensuring the integrity of the data. The supporting verification software meets the relevant requirements of FDA 21CFR part 11, is tamper proof, and traceable for tracking and auditing.
1、 Product advantages:
A、 Constructed with stainless steel 316L and PEEK materials, it is waterproof, corrosion-resistant, high-temperature resistant, and high-pressure resistant.
B、 Using high-precision PT100 temperature sensors and high-precision humidity and pressure sensors, the accuracy reaches ± 0.1 ℃/± 1.5% RH/± 0.25% full-scale, meeting the verification and detection needs of various fields, and the measurement range of various parameters is wide.
C、 Wireless small volume design, diameter 26mm, no wiring required, suitable for verification in various environments and devices
D、 Equipped with single hole and eight hole readers, USB connection for communication, convenient and fast reading of settings.
E、 The wireless verification probe has a memory capacity of over 32000.
F、 Multiple probes to choose from, hard probes/soft probes/no probes to choose from
G、 Users can replace the battery themselves, and the battery life is 2-3 years longer, depending on the specific situation.
H、 The software supports multiple systems, automatically collects relevant data, calculates F-values, and exports various verification reports. Compliant with FDA 21 CFR Part 11 and GMP requirements, with tracking and auditing capabilities, possessing CE certification and software copyright certificate.
IIWireless temperature and pressure verification probeparameter table
name |
Wireless pressure verification probe |
model |
DT-300Y |
pressure range |
0-100 PSI absolute pressure (0-680 kPa) (Equivalent to relative pressure: -100kpa~580kpa) |
resolution |
0.01 Kpa |
Pressure accuracy |
± 0.25% full scale |
Record capacity |
≥32000 |
sampling interval |
1 second to 24 hours |
material |
316L and PEEK |
Main body dimensions |
⌀26mm×67mm |
Sensor compartment size |
⌀8mm×10mm |
weight |
≈130g |
waterproof rating |
IP68 |
Replaceable battery |
3.6V lithium battery |
battery life |
2 years (typical application) |