Laboratory/Desktop LIBS Spectrometer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The laboratory integrated LIBS laser-induced breakdown spectroscopy system includes a laser, spectrometer, optical path acquisition system, 3D displacement table linkage control system, dual camera image linkage acquisition system, etc. It is very scalable and flexible, and is very suitable for users in scientific research, LIBS optical application experiments, optical application centers, etc. Multiple lasers and probes can be configured according to user needs, making it very convenient and flexible to select and configure lasers and spectrometers.

Product Details

实验室/台式LIBS光谱仪

LIBS laser-induced breakdown spectroscopy system

The LIBS (Laser Induced Breakdown Spectroscopy) laser-induced breakdown spectroscopy system focuses ultra short pulse laser on the surface of a sample to form a plasma. The emission spectrum of the plasma is analyzed using a spectrometer to identify the elemental composition of the sample, which can be used for material identification, classification, qualitative and quantitative analysis.

TrLIBS-LABlaboratoryThe LIBS laser-induced breakdown spectroscopy system mainly consists of a laser, high-resolution spectrometer, LIBS optical path collection probe, XYZ sample chamber, trigger delay controller, etc. Due to its modular design and strong scalability, it is very suitable for scientific research, LIBS optical application experiments, optical application centers and other users. Different lasers and spectrometers can be flexibly configured according to specific needs.

Main application areas

lCoal quality analysis and combustion product analysis

lOnline component analysis in the metallurgical industry

lMineral exploration and online analysis of ore quality

lSoil heavy metal analysis, biomaterials, aerosols, nanoparticles

lNuclear materials, waste, petroleum products

lBuilding materials, archaeology, casting, gold and jewelry testing

The detection limit of LIBS largely depends on the type of sample being tested, the type of element, and the specific selection and configuration of the laser and spectrometer. Based on the above reasons, the detection limit of LIBS can range from a few ppm to the% level. In most conventional applications, the LIBS detection limit can reach 10 ppm to 100 ppm for the vast majority of elements. In quantitative analysis, the relative standard deviation of measurement results obtained through LIBS can reach within 3-5%, while for homogeneous materials, it can usually be within 2% or even<1%.



The usual detection limit of LIBS

lElements such as Li, Be, B, Na, Mg, Al, K, Ca, etc.>10ppm, which is 0.001%

lTi, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo 等元素>100ppm即0.01%

lC. Elements such as N, O, P, Si, etc.>200ppm, which is 0.02%

lF. Cl, Br, S and other elements>0.5%



technical advantage

lThe broad scope of elemental analysis includesLight elements (such as C, H, O, N, Li, Be, B) and heavy elements with Z<12

llaboratoryLIBS system: including laser, spectrometer, optical path acquisition system, 3D displacement table linkage control system, dual camera image linkage acquisition system, etc

lLIBS spectral acquisition and analysis software, element peak matching recognition and online element concentration prediction, element concentration quantitative analysis modeling and analysis software (peak height method, peak area method, peak height ratio, peak area ratio)

lAnalysis speed is fast, ranging from seconds to minutes

lAlmost no sample preparation time is required, and solid samples or even powders (or excipients or adhesives) can be analyzed

lNo need for reaction reagents, more environmentally friendly, and safer

lRequires fewer samples than other elemental analysis instruments

lMicro level depth analysis and 3D mapping

lMicro analysis to macro analysis, targeted and flexible fixed-point precise analysis

lQualitative sample classification or quantitative element concentration

lMultiple laser and spectral acquisition probe options can be configured to meet your needs

lThe detection limit for most elements is10 ppm to several tens of ppm




Technical specifications

model

TrLIBS-LAB

Element measurement range

atomic numberZ ≥ 1 includes organic elements such as C, H, O, as well as light elements such as N, Li, Be, B, and almost all metallic and non-metallic elements

concentration range

10ppm to% level (depending on element and instrument configuration)

analysis time

<30S

analysis type

qualitative and quantitative analysis

spectrometer

Four channel spectrometer, wavelength λ = 190-820nm, Resolution 0.2nm

Eight channel spectrometer, wavelength λ = 190-1070nm, Resolution of 0.1nm

laser

Nd YAG: 266nm wavelength, 50mJ/pulse; Or 1064nm wavelength, 100-200 mJ/pulse

10Hz frequency, 5-10ns pulse width with built-in water cooling system

Sample window and positioning

XYZ three-axis fully automatic and freely positionable sample stage, with a stroke of up to 50mm,

Stepper motor drive, positioning accuracy5 µm

Sample imaging

Dual lens configuration,5x wide-angle lens for wide field observation

400x high magnification lens for precise micro positioning; Equipped with LED lighting

Analyze the size of the light spot

Minimum after focusing25µm

LIBS spectroscopy software

LIBS spectral data acquisition software, which can control (sample stage, laser, focusing,...)

Adjustment and control operations of imaging and other parameters