- Phone
-
Address
935, 9th Floor, Lanshuo Building, Dalang Street, Longhua New District, Shenzhen
Shenzhen Leotop Technology Co., Ltd
935, 9th Floor, Lanshuo Building, Dalang Street, Longhua New District, Shenzhen

Inductively Coupled Plasma Emission SpectrometerICP-OES PE 8000Introduction:
The Optima 8000 provides excellent resolution and linear dynamic range. More importantly, the stability and detection limit of 8000 are at a relatively high level. The performance of the 8000 series is achieved through optimizing the injection system, enhancing plasma stability, simplifying the establishment of the B method, and greatly reducing operating costs.
American PEInductively Coupled Plasma Emission SpectrometerOptima8000 (ICP-OES) has two models:
1. A desktop bidirectional observation device with a full wavelength range CCD array detectorInductively Coupled Plasma Emission SpectrometerIt has great flexibility and excellent analytical performance.
2. A desktop bidirectional observation device with two solid-state SCD detectorsInductively Coupled Plasma Emission SpectrometerIt has a detection limit of Z and true synchronous measurement function.
American PEInductively Coupled Plasma Emission SpectrometerOptima8000 Technical Parameters:
Strong adaptability, high salt and acid alkali resistance
The atomization system of Optima 8000 standard configuration is highly corrosion-resistant.
The atomizer is a GemConeTM atomizer designed by PerkinElmer, which is characterized by not clogging during high salt injection and can directly inject saturated salt solution! In addition, the atomizer nozzle has a corrosion-resistant gemstone nozzle, which gives it strong resistance to HF, alkali, aqua regia, and organic solvents!
The fog chamber is made of corrosion-resistant polymer materials, which are resistant to high concentrations of HF, alkali, aqua regia, and organic solvents. Moreover, this fog chamber has high physical strength, is not as fragile as glass fog chambers, has high sensitivity, good stability, and low memory effect.
In summary, the Optima 8000 injection system does not require the tedious operation of replacing the fog chamber and can perform analysis of 50% HCl, HNO3, H2SO4, 20% HF, and 30% NaOH. One injection system is equivalent to the standard configuration of other companies' injection systems+one organic injection system+one HF resistant injection system+one high salt resistant injection system.
Inductively Coupled Plasma Emission SpectrometerICP-OES PE 8000performance
The detection limits provided by PerkinElmer to users are based on data obtained from the standard HF acid resistant gemstone nozzle atomizer and HF acid resistant polymer material mist chamber of the instrument. If the user's sample does not contain HF acid or high salt content, they can also choose quartz concentric atomizer and cyclone mist chamber.