Shuangjie Testing Factory Phone 1520g/0.001g 0.1% Balance

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

G amp; The four performance indicators of the G2JJ1523BF Shuangjie Testing Factory telephone 1520g/0.001g one thousandth balance $r $n electronic balance: gas field. When using an electronic balance in daily life, the first consideration is the stability, sensitivity, accuracy, and invariance of the balance reading. The so-called stability refers to the stability of the accuracy of the balance; And sensitivity refers to the reaction speed of the balance reading, in which electronic balances have higher sensitivity than mechanical balances; Correctness refers to the accuracy of its reading, while invariance refers to the stability of the balance reading, that is, the fluctuation of the balance reading

Product Details

双杰厂电话

JJBF fully automatic internal calibration electronic analytical balance

G&G_JJ1523BF-Shuangjie Testing Factory Phone 1520g/0.001g 0.1% Balance

Product Description

·7 unit conversions: grams, carats, troy ouncesOunces, grams, pounds

·All aluminum alloy shell and glass windproof cover

·Electromagnetic balance sensor

·Counting function (sample size:1/10/20/50/100)

·Stainless steel scale pan

·Full weight peeling

·LCD liquid crystalDisplay screen with green backlight

·Built in calibration weights, fully automatic internal calibration

·Bottom with scale hook

·Horizontal adjustment of feet

·Horizontal indicator

model

JJ223BF

JJ323BF

JJ523BF

JJ623BF

JJ1023BF

Large scale weighing

220g

320g

520g

620g

1020g

Resolution (d)

1mg

1mg

1mg

1mg

1mg

Calibration division value (e)

10d

10d

10d

10d

10d

tare range

0~220g

0~320g

0~520g

0~620g

0~1020g

calibration method

Fully automatic internal school

Operating temperature (15-30)℃ (18-23)℃
Use humidity (40-80)%RH (50-70)%RH

Scale platform size

Φ90mm

Φ120mm
volume 220 (length) * 360 (width) * 345 (height) mm
power supply AC220V±10% 50Hz/60Hz
serial port RS232

JJ523BF

G&G_JJ1523BF-Shuangjie Testing Factory Phone 1520g/0.001g 0.1% Balance

How to choose an electronic balance? Choosing an electronic balance should consider whether it meets the accuracy requirements for weighing based on the accuracy (division value e) of the electronic balance. If choosing a balance with a precision of 0.1mg or 0.01mg, it is important not to generalize that a balance with a precision of one ten thousandth or one hundred thousandth should be used, as there are some foreign scales that require such precisionmanufacturerThe balance is measured by relative accuracy, otherwise the purchased balance cannot meet the needs of the user. For example, in practical work, when encountering a situation where a Mettler electronic balance with an actual scale division value d of 1mg, a calibration scale division value e of 10mg, and a large weighing capacity of 200g is used to weigh an object weighing 7mg, accurate results cannot be obtained. According to the "JJG98-90 Non Automatic Balance Trial Verification Regulations", the maximum allowable error is of the same order of magnitude as the calibration scale division value "e", and the maximum allowable error of this balance is 1e. Obviously, it cannot weigh an object weighing 7mg; Weighing an object weighing 15mg using this type of balance is not the best choice, as the relative error of its test results can be significant. A higher-level balance should be chosen, as some manufacturers have already specified the value for small weighing at the factory. Therefore, when choosing and using electronic scales, we must consider the accuracy level.

⑵ Requirements for symmetrical measurement range: When choosing an electronic balance, in addition to its accuracy, it should also be considered whether the large scale meets the requirements of the measurement range. Usually, adding a small safety factor to a large load is sufficient, which is commonly usedloadJust relax a bit more, not the bigger the better.

G&G双杰全国授权代理商