instrumentb2bPlease make sure to keep the standard plate of the multi angle glossiness meter clean
Multi angle glossiness meterThe working principle of is that the light source is directed towards the surface of the paint film on the test panel as a parallel or slightly converged beam through a lens. The reflected light is then converged by a receiving lens and absorbed by a photovoltaic cell on site to evaluate the physical quantity.
The multi angle glossiness meter is easy to operate. Generally, a suitable standard glossiness plate needs to be selected for calibration based on the surface glossiness of the test sample before measurement.
Multi angle glossiness meter refers to the ability and characteristics of the gemstone surface to reflect light.
1. The multi angle glossiness meter can measure the surface of different materials from plastic to metal, and has a wide measurement range. The glossiness range is 0-200Gu (measured at 20 degrees).
2. The measurement of glossiness difference can be carried out through standard value/sample value display or PASS/FAIL evaluation, or the PASS/FAIL function can be achieved by setting the limit difference.
3. You can select basic mode or statistical mode for measurement in the mode selection menu.
4. You can select the angle to be displayed on the angle measurement interface, and you can choose to display two or both angles simultaneously (MULTIDOSS268).
5. You can input the names of standard values and sample values in the measurement results for easy identification.
6Multi angle glossiness meterAutomatic diagnostic function for calibration.
Classification of Multi angle Glossmeters
Multi angle glossiness meters are classified into three types based on light intensity: high gloss, medium gloss, and low gloss.
According to the angle, it can mostly be divided into 45 degrees, 60 degrees, 75 degrees, 85 degrees, etc. Some manufacturers can produce dual angle or triangular glossiness meters. 85 degrees is a low gloss meter, and 20 degrees is a high gloss meter. Similarly, the most commonly used is the 60 degree gloss meter.
1. Multi angle glossiness meter belongs to optical precision instruments and should avoid severe impact. And try to place it in a dry, clean, and suitable temperature environment for use; When not in use, please place the detection window facing downwards to avoid contamination of the measuring lens; After the measurement is completed, please make sure to turn off the power and place the instrument in the instrument box in a relatively clean place for the next measurement.
2. Please make sure to keep the standard plate of the multi angle glossiness meter clean to avoid measurement errors caused by inaccurate readings during instrument calibration
3.Multi angle glossiness meterWhen the standard plate is stained, please wipe it with lens paper or lens cloth. Black standard plates can be wiped with lens paper dipped in anhydrous ethanol. After wiping with ethanol, white ceramic plates need to be dried in a drying oven (60 ° -65 °) for more than two hours.
4. To ensure more accurate measurement during measurement, calibration should be performed on the standard board after turning on the device. After completing the calibration of the glossiness meter, please do not turn the adjustment knob again to avoid measurement errors.
5. Please wait for a moment before taking measurements from places with lower temperatures to places with higher temperatures (such as outdoor to indoor in winter). (Due to the fogging of the surface of optical lenses from low to high temperatures)
6. Please do not measure in an environment where the measured object is directly exposed to sunlight to avoid affecting the measurement value.