Microcomputer BOD Biochemical IncubatorIt is an important experimental equipment for research institutions, colleges, production units or departmental laboratories in industries such as biology, genetic engineering, medicine, health and epidemic prevention, environmental protection, agriculture, forestry and animal husbandry, with the function of bidirectional temperature regulation system for cooling and heating, and temperature control. It is widely used in low-temperature constant temperature testing, cultivation testing, environmental testing, etc.
The microcomputer BOD biochemical incubator is used for the cultivation and preservation of bacteria, fungi, microorganisms, and tissue cells. It is an important experimental equipment for stability experiments and biological cultivation in laboratories of biology, genetic engineering, medicine, and other industries. The equipment has a vertical shape and a capacity of 80 liters. The box body and door are made of steel plate surface spray coating, and the structure of double-layer glass observation window is adopted. The box is equipped with controllable lighting, and the condition of the cultured items inside can be clearly observed without opening the box door. The studio uses mirror stainless steel plate, and there are multiple layers of partitions made of stainless steel wire that can be easily moved inside. The spacing between the partitions can be flexibly changed. The power switch, power indicator light, temperature controller, etc. are concentrated on the upper part of the box.
Microcomputer BOD Biochemical IncubatorTo extend the service life, the following points should be noted:
1. Before opening the biochemical incubator, it is necessary to fully familiarize oneself with the user manual and master the correct usage method. To maintain the service life of the biochemical incubator.
2. Biochemical incubator It should be placed in a place with less dust and minimal temperature changes. The box must be grounded, using a three pin plug, and the socket should be properly grounded.
3. The inside and outside of the biochemical incubator should be kept clean daily, and should be cleaned after each use. Long term use should be covered with a plastic dust cover and placed in a dry room. At the same time, the inner walls and equipment surfaces of the box should be regularly wiped to maintain cleanliness and increase the transparency of the glass.
True color touch screen biochemical incubator
4. During work, frequent opening of doors should be avoided to maintain temperature stability and prevent dust and dirt from entering.
5. Stop using the biochemical incubator, turn off the main power button and the power switch at the back of the equipment.
6. To ensure effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 100mm. There should be a 50mm gap on the side of the box, and at least 300mm of space at the top of the box.
7. It is strictly prohibited to store volatile chemical solvents, explosive gases, and flammable gases inside the box; Combustible sprays shall not be used near the biochemical incubator to avoid spark ignition.
8. After the cultivation is completed, please pay attention to cutting off the power in a timely manner, and dispose of items promptly and properly when taking them out.
Microcomputer BOD Biochemical IncubatorOperating Procedures
1. Connect the power supply to the incubator and turn on the power switch.
2. Select the switch according to the parameters, adjust the temperature and turn it to the desired temperature. At this point, the set temperature will display the desired temperature. The heating indicator light is on, and the measured temperature gradually approaches the set temperature.
3. Open the incubator door, place the desired items for cultivation into the incubator, close the door and cultivate.
4. After the cultivation is completed, take out the items.
5. Close the incubator door and cut off the power supply.
Microcomputer BOD Biochemical IncubatorNotes:
1. The device uses a three pin plug, and the socket should be properly grounded.
2. To ensure effective heat dissipation during condensation, the distance between the condenser and the wall should be greater than 100MM.
3. It is strictly prohibited to store volatile chemical solvents, explosive gases, and flammable gases inside the box; Flammable sprays shall not be used near the incubator to avoid spark ignition.
4. To prevent pollution, try to avoid condensation of ice beads on the walls of the workspace during low-temperature use.
5. Place the test equipment on the incubator rack, and maintain an appropriate distance between each test bottle to facilitate the convection of hot and cold air.
6. During work, frequent opening of doors should be avoided to maintain temperature stability and prevent dust and dirt from entering.