Welcome Customer !
instrumentb2bLovibond upgrades TC series BOD constant temperature incubator

Lovibond 升级 TC系列 BOD 恒温培养箱Lovibond®Roewe State, Germany®water quality analysis

Lovibond upgrades TC series BOD constant temperature incubator


old versionTC 255 S,TC 256 G,TC 445 SDiscontinued, please select the corresponding updated version. For inventory of discontinued models, please consult Lovibond China or our cooperating agents.

Lovibond®BD600 BOD productionChemical Oxygen DemandMeasuring instrument BD600adoptPressure difference method, also known asBreathing methodThe testing principle of Manometric and Respirometric Method.

When testing the BOD of wastewater, in 20℃ constant temperature conditionBelow, the water sample isenclosedBODSample bottleIn the cultivation reaction, microorganisms use organic matter in water samples as an energy source, consuming oxygen to decompose organic matter and produce carbon dioxide.

Lovibond 升级 TC系列 BOD 恒温培养箱


Organic matter is oxidized by microorganisms, partially or completelyDecompose into carbon dioxide(CO2)And inorganic salts. potassium hydroxideabsorbentAbsorb the product carbon dioxide from the gas phase of the sample bottle,BODSample bottle appearspressure differenceThe pressure difference is proportional to the amount of oxygen consumed.
Lovibond®BD600Sewage BODdetermination(T = 20 °C ± 1 °C)comply withEN 1899, APHA,AWWA, WEF Standard Methods 5210 D, OECD 301 F, 301 C, 302 CSewageBODMeasurement for general useFive day cultivation methodGet itBOD5 mg/L O2 Numerical value. Industrial water samples and users without compliance requirements can be selected based on actual applicationsSelect the appropriate cultivation temperature to test and obtain the corresponding BOD value.
—
BOD reaction temperature


Temperature has a significant impact on biological activity and affects the pressure difference methodBODThe calculation has an impact.BODThe measuring instrument should always be at a temperature of20°CCultivate the reaction in a constant temperature incubator.

Lovibond®TCseriesBODThe constant temperature incubator isBD600 BODbiochemical oxygen demandTailored measuring instrument.


Lovibond 升级 TC系列 BOD 恒温培养箱


Lovibond 升级 TC系列 BOD 恒温培养箱 T = 20 °C ± 0.5 °C



TCseriesBODThe temperature range of the constant temperature incubator can be within2 °Cto 40 °C Continuous adjustment,The error is ± 0.5 ℃SatisfyBODCultivate requirements (± 1 ℃) and be suitable for various applications in industry and research laboratories. The integrated temperature control unit complies withEMCcommandIEC 61326Electrical equipment used for measurement, monitoring, and laboratory use.


Lovibond 升级 TC系列 BOD 恒温培养箱Environmentally friendly refrigerant, variable frequency energy-saving


Using environmentally friendly refrigerants,2024 Upgraded VersionTCseriesBODThe constant temperature incubator adopts variable frequency refrigeration, and the same size model can achieve up topower saving34%!


Lovibond 升级 TC系列 BOD 恒温培养箱Built in power supply,LEDdisplay status


The temperature can be0.1 °CStep size setting,LEDThe display screen shows the set temperature and current temperature in the constant temperature incubator.BD600 BODThe measuring instrument can be directly connectedPower socket inside the constant temperature incubatorThe internal space and grid load-bearing capacity areBD600量身定制。


Lovibond 升级 TC系列 BOD 恒温培养箱Glass doors and different sizes to choose from


use in combinationBD600The remote control checks the data outside the thermostat to avoid temperature fluctuations caused by opening the door. Different sizes of incubators meet the requirements3-9TaiwanBD600Simultaneously testing.G is the glass door model, and S is the standard steel door model.


Lovibond 升级 TC系列 BOD 恒温培养箱update status


old versionTC 255 S,TC 256 G,TC 445 SDiscontinued, please select the corresponding updated version. TC 135 S and TC 140 G are still available for normal supply.


Lovibond 升级 TC系列 BOD 恒温培养箱
Lovibond 升级 TC系列 BOD 恒温培养箱



Latest News