Welcome Customer !

Membership

Help

Yangzhou Lufeng Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Article

Yangzhou Lufeng Electric Co., Ltd

  • E-mail

    yzlufengdq@163.com

  • Phone

    13348124356

  • Address

    Yanyang Avenue, Industrial Concentration Zone, Liubao Town, Baoying County, Jiangsu Province

Contact Now
Technical specifications of waveform recorder
Date: 2025-11-30Read: 2

Product Overview

The waveform recorder is a transient signal recording instrument developed for power system applications. The internal software of the instrument is pre-set with a test template for generator debugging, allowing users to easily complete the generator through the recorderThree phase short-circuit characteristic curve, no-load characteristic curve, load rejection test, self synchronization verification test, excitation system disturbance test, excitation system frequency and voltage characteristic test, excitation system demagnetization time constant measurement, generator phase advance test, generator rotor AC impedance test, power analysis test, excitation systemProcess records of PSS test, motor start-up test, transformer impact test, power system fault diagnosis, etc.

The instrument has rich software components that allow users to perform graphic analysis, combinatorial operations, effective value calculation, AC power calculation, three-phase symmetry analysis, spectrum analysis, harmonic analysis, curve correlation analysis, graphic editing, and phasor diagram drawing through software components. Experimental data and analysis results can be generatedThe test report can be in WORD/EXCEL format, and JPG images can also be generated and exported through software to facilitate users' in-depth analysis and processing of the test results.

The instrument has12 analog inputs, 12 active switch inputs, and 3 output signals, with a sampling frequency of up to 100KHZ, can basically meet the transient signal recording requirements of various tests in power systems. And all simulated channels are isolated from each other to avoid connection problems between different potential points during the experiment, which may cause faults in the tested system.

Features

1、 Real time drawing of experimental curves and providing multiple curve analysis tools, allowing users to perform arbitrary scaling and positioning operations on the curves

2、 It is possible to edit the graphics in the current oscilloscope, including free identification, color transformation, etc., to facilitate the production of test reports

3、 Provided spectrum analysis tools to enable users to easily obtain spectrum graphs of signals

4、 You can choose any signal asDraw the relationship curve of signals on the X-axis and Y-axis

5、 Provided a harmonic analysis tool that can perform harmonic analysis on the collected signals, with a harmonic order of1024 times

6、 Combination operation tools enable users to perform operations such as addition, subtraction, multiplication, division, and integration on the collected signals

7The Calculate the effective value and power of the selected channel signal

8、 Perform power and symmetry analysis on the selected three-phase signal

9、 Draw a phasor diagram of the selected signal

10、Select channel signal type through software: DC instantaneous value or AC effective value

11、 Built in standard test templates for generator three-phase short-circuit characteristic curve, no-load characteristic curve, load rejection test, self calibration synchronous verification test, excitation system disturbance test, excitation system frequency and voltage characteristics, excitation system demagnetization time constant measurement, generator phase advance test, generator rotor AC impedance test, power analysis test, and software automatic calculation of test result parameters.

12、The instrument can complete the generatorPSS test recording, transformer impact test recording, motor start-up test recording, power system fault recording and other process records

13、The instrument can automatically generateWORD test report, Excel test report

14、 Automatic identification of curves in test reports enables automated production of test reports

15、 The names and units of all sampling channels can be redefined

16、 Automatic saving of experimental environment and instrument settings for various experiments

17、 Automatically calculate test parameters for various test templates

18、 Simple and convenient channel filtering method

19、 useConvenient export of test data from storage devices such as USB flash drives or portable hard drives

20、 The Windows XPE operating system can achieve self-protection and recovery of software systems, preventing virus attacks and erosion

21、 Adopting anti shake processing to avoid user error operations

technical indicators

1. 12 channels of low voltage/current analog signal acquisition, voltage input range -10V~10V, -200V~200V, -400V~400V, current input range -20mA~20mA, 1 channel of analog signal -100mV~100mV input channel (100mV channel allows input voltage<10V)

2. Voltage channel input range, voltage or current signal type selection, selected through software

3. Signal acquisition error

-400V~400V <0.5V

-200V~200V <0.2V

-10V~10V <0.01V

-20mA~20mA <0.02mA

-100mV~100mV <0.2mV

4. Indirect calculation of data error

frequency measurement30-170Hz <0.1Hz

Active power and reactive power measurement:0.5%RDG+0.05%FS

Direct method for measuring power angle error of generator<3 degrees

Indirect method for measuring power angle error of generator<8 degrees

5. 12 active node switch measurement channels, switch signal range DC12-2220V

6. 3 switch output channels, with an open/close capacity of AC220V/1A

7. Split type chassis structure, the operating terminal allows users to more conveniently control experiments and analyze data

8. 2 USB ports for data download or keyboard/mouse input

9. 12.1-inch large color screen display, touch screen mode for human-machine interaction

10. The instrument comes with 8GB of data storage space

11. Sampling channel input impedance

-10V~10V voltage range input impedance820k euros

-200V~200V voltage range input impedance820K euros

-400V~400V voltage range input impedance820K euros

-20mA~20mA current range input impedance50 euros

-Voltage range of 100mV~100mVinput impedance >10M