Fangyuan Building Coating Permeability Test Device (Funnel)
Date: 2018-05-15Read: 0

Test device for permeability of architectural coatings

Parameters of the permeability test device (funnel) for architectural coatings;
After sandblasting treatment
Volume;95ml(5mlDifference)
Scale on the upper glass tube;4ml
Zui small division value;0.1ml
Chassis diameter;65mm-66ml

Product Details

The purpose of the permeability test device (funnel) for architectural coatings;

Both interior and exterior wall primers or multi-layer building coatings must be tested for impermeability of their coatings

The permeability test device (funnel) for architectural coatings meets the standard;Compliant with JG/T 201 "Primer for Interior and Exterior Walls of Buildings" standard,

Technical guidance for permeability testing device (funnel) of architectural coatings;

The volume is 95 ± 5ml, the upper glass tube has a 4ml scale, the smallest scale value is 0.1ml, and the diameter of the frosted chassis is 65ml to 66ml;

Test method for permeability test device (funnel) of architectural coatings;

1.During the experiment, place the sample coated and dried test panel in a horizontal position, and place the impermeable test funnel in the middle of the test panel;

2.Seal the gaps around the test panel and funnel with non absorbent sealing material to ensure that water does not seep out from the gaps. After the sealing material is dried, introduce the test water into the glass tube;

3.Adjust the zero mark of the test tube again after confirming that there are no bubbles in the container until it reaches the zero mark;

4.Cover the top of the glass tube with tin foil and let it stand for 24 hours under the specified test conditions;

5.Evaluate the impermeability of the sample by the number of milliliters of liquid level drop.

1、 According to the standard:

GB/T 9755-2014Synthetic resin lotion exterior wall coating appendixBPermeability test.

2、 Technical parameters:

For a funnel-shaped glass device with a scale, volume(95±5)mlThe upper glass tube is equipped with4mlScale, the smallest division value is0.1mlThe diameter of the chassis is approximately65-66mmAfter sandblasting treatment. As shown in the figure below