Merck RQflex 20 Reflector Product Number: 1.17246.0001, Germany

1、 Test strip - immersion - reading - recording - taking measures

RQflex 20 is compact and easy to use, making you feel like you're in a laboratory. Mainly used for raw material detection or residual monitoring after disinfection in the production process, accurate quantitative test results can be quickly obtained on site.

The Reflectoquant system consists of a reflectometer and a matching RQ test strip. This portable laboratory solution provides you with all the necessary testing tools, mainly used for high-quality and low-cost on-site analysis and testing of food and beverage, soil, water and other samples.

1. Intuitive navigation menu

The new Chinese menu is simple and easy to use, allowing you to access all testing methods, test results, and analysis quality assurance options, as well as customize various settings according to your own needs.

The Chinese display screen shows simple and easy to understand test methods and operation process diagrams, making it convenient for you to start testing directly and quickly obtain accurate and reproducible test results.

2. Portable analysis

Lightweight and compact, like a mobile laboratory, it can directly analyze and test key indicators on site and obtain quantitative results. You can obtain test results within a few minutes, making it easy for you to monitor the raw materials throughout the entire production process.

3. Barcode test strip with batch information calibration function

Each batch of RQ test strips comes with a barcode with batch calibration function inside the packaging box, ensuring accurate and reproducible results. The accuracy can reach ± 10% of the middle range of the test range.

4. Instrument supports analysis quality assurance function

In the Quality Assurance Function (AQA) analysis, the RQcheck testing suite and the entire System Monitoring (TSM) process can ensure that you receive accurate measurement results. Instrument baseline calibration is intuitive and simple, allowing you to always obtain reliable test results.

5. Detailed testing methods and application instructions to meet your testing needs

We provide comprehensive and rapid instrument analysis solutions covering the determination of ammonia nitrogen, nitrate, and other substances, such as sugar content in chocolate, nitrite content in vegetables, or hydroxymethylfurfural in honey.

6. Simplify your analysis through timers

To maximize your efficiency, a timer with advanced warning functions can be customized according to your workflow to sound an alarm before the test strip preparation time ends.

7. Supports multiple languages

English, German, French, Spanish, Portuguese, Japanese, and Chinese are optional.

2、 Application

The Reflectoquant application instructions provide specific steps for sample preparation and detailed information on how to measure various parameters in agricultural, food and beverage, or disinfection residue control processes.

1. Agriculture: Controlling Nutrients in Soil and Plant Products

Like nitrogen, phosphorus is also a nutrient element that plants require in large quantities during their growth process. Overfertilization may occur in agricultural production, so analyzing these parameters is crucial.

2. Disinfection residue control: 0.1% peracetic acid is sufficient to kill bacteria, viruses, fungi, and spore forming bacteria in the shortest possible time

Therefore, it is often used in infectious low-temperature disinfection processes such as beverage packaging bottles. Complete disinfection residue control includes analysis within high and low concentration testing ranges.

3. Food and Beverage

(1) Rapid quantitative analysis of hydroxymethylfurfural content in honey

The freshness of honey can be determined by measuring its hydroxymethylfurfural (HMF) content. HMF is an organic compound produced during the dehydration process of fructose, such as heating for packaging convenience. HMF is almost undetectable in fresh honey, and then increases at a rate of about 2.3mg/kg/year (depending on storage temperature and pH value).

At 21 ℃, the HMF content can rise to 20mg/kg in just one year.

(2) Determination of Vitamin C in Food and Beverages

Vitamin C (ascorbic acid) is a frequently tested parameter in many food and beverage industries. The reduction of this ingredient will cause a decrease in quality and taste, so it is necessary to test its content.

(3) Detecting Acrylamide

In fried or baked goods such as potato chips, the reaction between asparagine and reducing sugars (fructose, glucose, etc.) may produce acrylamide, which is considered a toxic carcinogen. Therefore, the reducing sugar in potatoes should not exceed the allowable amount.

3、 Technical parameters

Item number: 1.17246.0001

Size: 184 * 79 * 30mm

Weight: 253g (including battery)

Memory: 50 sets of test methods, 200 sets of measurement results, 50 sets of RQcheck test results, and 50 sets of calibration data.

Light source: 4LEDs, green/red, dual beam test

Power supply: 4 1.5-V batteries (AAA)

Display: Reflective LCD graphics module (256 * 160 dots)

Measurement range: 4-90%

Reflection area: 4 * 6mm

Resolution: 0.1%

Operating temperature: 5-40 ℃

Operating humidity: below 80%

4、 Testing specifications of RQflex 20 reflectometer

test parameters

Test range

Test count

Order Number

ammonia nitrogen

0.2-7.0 mg/l

50

1.16892.0001

ammonia nitrogen

5.0-20.0 mg/l

50

1.16899.0001

ammonia nitrogen

20-180 mg/l

50

1.16977.0001

Vitamin C

25-450 mg/l

50

1.16981.0001

Blank bar

50

1.16730.0001

calcium

5-125 mg/l

50

1.16125.0001

residual chlorine

0.5-10.0 mg/l

50

1.16896.0001

formaldehyde

1.0-45.0 mg/l

50

1.16989.0001

glucose

1-100 mg/l

50

1.16720.0001

Hydroxymethylfurfural (HMF)

1.0-60 mg/l

50

1.17952.0001

iron

0.5-20.0 mg/l

50

1.16982.0001

20-200 mg/l

50

1.16983.0001

lactic acid

1.0-60.0 mg/l

50

1.16127.0001

magnesium

5-100 mg/l

50

1.16124.0001

malic acid

5.0-60.0 mg/l

50

1.16128.0001

nitrate

3-90 mg/l

50

1.16995.0001

nitrate

5-225 mg/l

50

1.16971.0001

nitrite

0.5-25.0 mg/l

50

1.16973.0001

nitrite

0.03-1.00 g/l

50

1.16732.0001

Peracetic acid

1.0-22.5 mg/l

50

1.16975.0001

Peracetic acid

20.0-100 mg/l

50

1.17956.0001

Peracetic acid

75-400 mg/l

50

1.16976.0001

peroxide

0.2-20.0mg/l

50

1.16974.0001

peroxide

20.0-100mg/l

50

1.17968.0001

peroxide

100-1000 mg/l

50

1.16731.0001

PH value

1.0-5.0

50

1.16894.0001

4.0-9.0

50

1.16996.0001

PH value (condensing lubricant)

7.0-10.0

50

1.16898.0001

phosphate

5-120 mg/l

50

1.16978.0001

potassium

0.25-1.20 g/l

50

1.16992.0001

sucrose

0.25-2.5 g/l

50

1.16141.0001

sulfite

10-200 mg/l

50

1.16987.0001

Total Hardness

0.1-30.0°d

50

1.16997.0001

Total sugar (glucose and fructose)

65-650 mg/l

50

1.16136.0001