Merck Karl Fischer Reagent Selection Guide from Germany
Date: 2025-11-27Read: 2

Merck Karl Fischer reagent from Germany

The Karl Fischer titration method has been widely used worldwide since its discovery in the 1830s. Due to its wide range of moisture detection, it can be applied to various material samples such as food, chemicals, pharmaceuticals, cosmetics, and mineral oils. The Karl Fischer titration method is based on a chemical reaction with water to detect water content, and can accurately determine water.

At present, the Karl Fischer titration method has been listed as a standard guidance method by pharmacopoeias, SOPs (Standard Operating Procedures), ISO9000ff, ASTM (American Society for Testing and Materials), and DIN (German Institute for Standardization) in various countries. The Karl Fischer titration method is fast, accurate, and stable, and is not affected by sample type, aggregation state, or the presence of volatile substances.

Karl Fischer titration reagent: has a wide range of applications and can be used for products with a moisture content of 0.1-100%.

Application instruments:

(1) Swiss Wantong: 758 KFD Titrino Multipurpose Volumetric Moisture Analyzer, 795 KFD Titrino Extended Volumetric Moisture Analyzer, 787 KF Titrino Specific Volumetric Moisture Analyzer

(2) Mettler: DL31 Kjeldahl Capacity Meter, DL38 Kjeldahl Capacity Meter

Karl Fischer Coulomb reagent: high titration accuracy, versatileYuProducts with a moisture content of less than 1%

Application instruments:

(1) Swiss Wantong: 756 KF Coulometer Extended Coulometer Karl Fischer Moisture Analyzer, 831KF Coulometer Practical Coulometer Karl Fischer Moisture Analyzer

(2) Mettler: DL32 Karl Coulomb apparatus, DL39 Karl Coulomb apparatus

Order N.O

Order Number

PACK

packaging

Product Name

Product Name

1.88005.0500

500ML

apura-CombiTitrant 5 , 1ml--5mg H2O

Single component titrant 1ml-5mg H2O

1.88005.1000

1L

apura-CombiTitrant 5 , 1ml--5mg H2O

Single component titrant 1ml-5mg H2O

1.88002.0500

500ML

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-2mg H3O

1.88002.1000

1L

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-2mg H3O

1.88001.0500

500ML

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-1mg H4O

1.88001.1000

1L

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-1mg H4O

1.09248.1000

1L

Karl Fischer reagent 5 single component reagent w

Single component titrant 1ml-5mg H5O containing pyridine

1.88008.1000*

1L

apura-CombiSolvent methanol-free

Single component solvent, methanol free

1.88020.1000*

1L

apura-Solvent for the one component titration for

Single component solvent, oil specific

1.88021.1000*

1L

apura-Solvent for the one component titration for

Single component solvent, specifically designed for food oil

1.88010.0500

500ML

apura-Titrant 5 , 1ml--5mg H2O

Two component titrant 1ml-5mg H2O

1.88010.1000

1L

apura-Titrant 5 , 1ml--5mg H2O

Two component titrant 1ml-5mg H2O

1.88011.0500

500ML

apura-Titrant 2 , 1ml--2mg H2O

Two component titrant 1ml-2mg H3O

1.88011.1000

1L

apura-Titrant 2 , 1ml--2mg H2O

Two component titrant 1ml-2mg H3O

1.88015.1000

1L

apura-Solvent for the two component titration

Two-component solvent

1.88016.1000

1L

apura-Solvent for the onetwo component titrati

Two component solvent, specifically designed for oils and fats

1.09257.0508

500ML

apura-CombiCoulomat fritless for cells withw

Coulombic reagent (non membrane specific)

1.09255.0508

500ML

Apura-CombiCoulomatfrit

Coulombic reagent (for membrane reaction tanks)

1.88050.0010

10x8ml

apura-Water Standard 0.01%

Standard water sample 0.1%

1.88051.0010

10x8ml

apura-Water Standard 0.1%

Standard water sample 1%

1.88052.0010

10x8ml

apura-Water Standard 1%

Standard water sample 1%

1.09259.0250

250ml

apura-Water standard (1 ml contains 5mg H2O)

Standard water sample 0.06%

1.12939.0010

10g

apura-Lactose standard 5% solid standard for C/V/O

Standard water sample 0.07%

1.06664.0100

100g

apura-Sodium tartrate dihydrate volumetric standar

Sodium tartrate dihydrate

1.05704.0250

250g

Molecular sieve 0.3 nm beads about 2 mm LAB

Molecular sieve 0.3nm

Karl Fischer single component reagent

Item Number

use

advantage

Apura-CombiTitrant5

5 equivalents of single component titrant

1.88005.1000

Widely used reagents

1ml titration of 5mgH2O

1. Faster titration;

2. Clearer titration endpoint;

3. Constant commitment and consistent high quality;

4. Non toxic mixed solution, safer;

5. The solvent can be prepared according to different samples.

Apura-CombiTitrant2

2 equivalents of single component titrant

1.88002.1000

More suitable for titrating samples with lower moisture content

1ml titration of 2mgH2O

Apura-CombiTitrant1

1 equivalent of single component titrant

1.88001.1000

Suitable for samples containing trace amounts of moisture

Titrate 1mg H2O with 1ml

Apura-CombiSolwent

Single component solvent

1.88008.1000

Does not contain methanol, meeting the requirements for faster and more accurate single component titration

Special solvent containing methanol as a single component

1.88009.1000

Moisture content not exceeding 0.01%

CombiMethanol dried

(max.0.0005% H2O), SeccoSolv anhydrous methanol (moisture content less than 0.0005%)

1.06012.0500

Moisture content not exceeding 0.01%

1. Faster titration;

2. Does not contain harmful alcohols;

3. Inhibit side reactions without precipitation;

4. Mentioning accuracy and reproducibility;

5. Constant commitment and consistent high quality.

Aldehyde ketone titrant

1.88006.1000

Aldehyde ketone specific type, can also be used for non aldehyde ketone products

1ml titration of 5mgH2O

Aldehyde ketone solvent

1.88007.1000

Aldehyde ketone specific solvent