Milton Roy metering pumps have a wide coverage and a variety of types!
Date: 2017-10-18Read: 18
The common types of Midon electromagnetic metering pumps include Midon electromagnetic pump P series, Midon electromagnetic metering pump AD series, Midon electromagnetic metering pump B series, Midon electromagnetic metering pump C series, Midon electromagnetic metering pump E series, Midon electromagnetic metering pump HH series, etc. The flow range is from 0.69L/H to 95L/H. The maximum pressure can reach 20.7 bar, and there are multiple pump heads to choose from. Equipped with automatic overvoltage protection, no need to install safety valves; Wide flow range adjustment, up to 1000:1; Multiple control methods such as external pulse control, 4-20mA signal control, and signal feedback control can be selected. The moving parts are simple, do not require lubrication or rotation, and are reliable. Module design, no need for welding, low energy consumption and other characteristics.
The Milton Roy Mechanical Diaphragm Metering Pump Series includes the Milton Roy Mechanical Diaphragm Metering Pump GM Series, Milton Roy Mechanical Diaphragm Metering Pump GB Series, and Milton Roy Mechanical Diaphragm Metering Pump GMA Series, with a single head flow rate of up to 1800L/H; The maximum pressure can reach 12 bar; There are various pump heads available, including PVC, PVDF, SS316L, high viscosity, sodium hypochlorite pump head, slurry pump head, etc. The drive end adopts a variable eccentric mechanism for adjustment, ensuring smooth flow pulses. The enhanced structural design is suitable for harsh use environments, and the wear-resistant ball bearings make the work more stable. The oil bath lubrication prolongs the working life of the drive components. The flow can be adjusted in both parking and running states, and manual, electric, variable frequency, and pneumatic modes can be used for adjustment.
Milton Roy metering pump is in the metering pump industry, from the first invention of metering pumps to the development and production of * metering pumps. Its products cover multiple types such as LMI electromagnetic metering pumps, G series mechanical diaphragm metering pumps, hydraulic diaphragm metering pumps, plunger pumps, etc., which can meet the needs of different industries. During the operation of the Milton Roy metering pump, various malfunctions may occur. How should on-site personnel handle the situation when the pump output is insufficient?
Fault analysis and solution for insufficient liquid output of the pump:
1. The stroke setting is incorrect. Adjust the stroke setting again.
2. The pump is running at an incorrect speed. Match the power supply voltage and frequency with the data on the pump motor label.
3. Insufficient liquid absorption. Increase the diameter of the pipette or increase the suction head.
4. Leakage of pipette. Repair the suction pipeline.
5. The suction distance is too high. Rearrange the equipment to reduce the suction stroke.
6. The liquid is close to boiling point. Cooling liquid or increasing suction head.
7. The safety valve in the outlet pipeline is leaking. Repair or replace the safety valve.
8. The viscosity of the liquid is too high. Reduce viscosity (such as heating or diluting liquids).
9. Wear or contamination of the one-way valve seat. Clean or replace.