What preparations need to be made before operating an automatic tablet press in the laboratory
Date: 2025-08-20Read: 3
Automatic tablet press for laboratory useIt is an intelligent device that achieves precise pressurization, pressure holding, and pressure relief through programmed control, widely used in the fields of material preparation and sample analysis.
Application Scenario:
Material research and development - compression molding of polymer composite materials, ceramic powders, and battery materials.
Spectral analysis - Prepare standard samples for infrared spectroscopy (FTIR) and X-ray fluorescence (XRF) detection.
Quality Inspection and Research - Uniformity Testing of Pharmaceutical Tablets, Preparation of Environmental Monitoring Samples, Mineral Metallurgical Powder Compression Samples.
Product Features:
Compact structural design
Press the sample and accept all standard mold sets within a few minutes
Programmable LCD touch screen interface
Programmable parameters include pressure, dwell time, and release time
The safety function includes a safety interlock device that maintains the chamber door during operation
In the locked position. It is also equipped with an automatic pump to close the safety valve
Preparation before operation:
Equipment inspection and environmental settings:
Confirm that the power supply grounding of the tablet press is stable, the protective cover (usually made of polycarbonate material) and safety interlock device are intact, and avoid high voltage operation risks.
Clean the workbench and mold to ensure that there is no residual powder affecting the uniformity of the sample.
Suggest watching a demonstration of safe operation:
Parameter preset (core steps)
Set the program through the touch screen or control panel, including pressure (8-40 tons), holding time (0-999 seconds), mold diameter (such as 20/40/60mm), and adjust the gradient pressure and exhaust frequency according to the sample type.
Example: Select "Auto Mode", enter the pressure value (such as 20 tons), holding time (30 seconds), and turn on the timer switch to ensure the countdown takes effect.