Precautions for oscillating light incubator
Date: 2025-12-23Read: 0
  1. pollution preventionWhen using at low temperatures, try to avoid condensation of frost on the walls of the working chamber as much as possible.

  2. Usage environmentNot applicable to the cultivation of items containing volatile chemical solvents, low concentration explosive gases, low ignition point gases, and toxic substances.

  3. Avoid direct sunlightThe whole machine is strictly prohibited from being used in an environment with direct sunlight.

  4. speed regulation methodSpeed regulation should start slowly from low speed to high speed.

  5. maintenanceProper use and maintenance of the incubator to keep it in good working condition can extend its lifespan.

  6. Heating object processingHeating objects should be cooled at ambient temperature before being placed in the machine. It is strictly prohibited to directly place heating objects in the refrigeration incubator to prevent danger.

  7. Refrigeration system usageWhen the refrigeration system is working, unless necessary for experiments, frequent opening of the box door should be avoided, which is beneficial for maintaining temperature stability and preventing dust and dirt from entering.

  8. Cleaning and maintenanceAfter the refrigeration system stops working, wipe the working chamber clean with a soft cloth. When cleaning the machine, the power should be unplugged first.

  9. safe operationUsing at medium speed within the speed range can extend the lifespan of the instrument.

  10. placement locationThe full temperature light oscillation incubator should be placed on a flat ground, the environment should be kept clean and tidy, ventilated and dry.

  11. Power connectionConnect the external power supply, place the power switch in the "on" position, and the indicator light will turn on.

  12. Temperature settingPress the SET key to set the temperature. Press the SET key until the data in the lower row of the convergence tube flashes, indicating that the instrument has entered the temperature setting state. Press the △ key to increase the set value, press the ▽ key to decrease the set value, and then press the SET key again to return the instrument to normal working state. The temperature setting is complete.

  13. Oscillation switchTurn on the oscillation switch, the indicator light is on, slowly adjust the speed control knob to reach the desired speed.

  14. End of work processingAfter completing the work, set the temperature control button and speed control knob to the minimum value, and cut off the power supply