The multi parameter 2099pro is a specialized water quality monitoring equipment for secondary water supply pump rooms, with high integration and convenient operation as its core advantages, adapted to the water quality monitoring needs of pump room scenarios. Its structural design, installation requirements, and maintenance methods are as follows:
-
Parameters and InterfaceCan synchronously monitor temperature, conductivity PH、 Dissolved oxygen, residual chlorine, and turbidity are six core parameters, with a simple interface operation that supports viewing real-time curves, historical data, parameter settings, and calibration. On site viewing is intuitive and clear.
-
Structural partitioningDivided by the waistline, the upper part is the electronic unit (including the motherboard, measuring board, and display screen), and the lower part is the waterway structure. The interior is equipped with file storage slots and decorative light strips, balancing functionality and practicality; The waterway system includes a flow meter (standard, adjustable, stable water flow, saving water resources) and an inlet double safety valve (flow meter valve+inlet end valve) to ensure the controllability of the waterway.
-
Sensor characteristicsUsing digital sensors, combined with movable threads and split cables, conductivity, pH and other sensors can be disassembled, replaced, maintained or returned to the factory separately, supporting flexible parameter adjustment (such as removing conductivity, dissolved oxygen, or adding conductivity), adapting to different monitoring needs.
The equipment size is 1.1 meters high, 480mm wide, and 460mm thick. Installation should focus on drainage: the drainage end should be as low as possible, and if the drainage ditch is on the horizon, it can be directly placed on the ground for use; If the drainage belt extends out of the pipeline, the equipment should be raised to avoid backflow or poor drainage (otherwise there may be water seepage, and the drainage problem should be checked first rather than equipment failure); The horizontal height of the water inlet should be higher than the designated position to ensure the normal flow of the waterway.
There are grilles (for buffering and defoaming purposes) and independent turbidity compartments (for stable water flow without bubbles) in the waterway. When cleaning, open both compartment valves and flush for 5-10 minutes without closing the inlet valve to discharge the bottom sand and gravel; When conditions permit, 6 screws can be removed to open the lid and flush. After completion, close the valve and wait for the cabin to be filled with water and stable for 10 minutes before use. Maintenance is convenient and efficient.