Technical parameters of online conductivity meter
Date: 2016-10-26Read: 38
Technical parameters of online conductivity meter

Standard:
JB/T 6855-93 "Industrial Conductivity Meter";
Measuring range:
0.01-20 μ S/cm (with 0.01 electrode), can actually reach 100.0 μ S/cm;
0.1-200 μ S/cm (with 0.1 electrode), can actually reach 1000.0 μ S/cm;
1.0-2000 μ S/cm (with 1.0 electrode), can actually reach 10.00mS/cm;
10-20000 μ S/cm (with 10.0 electrode), can actually reach 100.0mS/cm;
Temperature compensation:
0-99.9 ℃, with 25 ℃ as the reference temperature;
Tested water sample:
0~99.9℃ ,0.6MPa;
Basic error:
Conductivity: ± 1.0% FS, Temperature: ± 0.5 ℃ (0-60 ℃);
Repeatability:
± 0.2%FS
Stability:
±0.2%FS
Current isolation output:
0-10mA (load<1.5k Ω), 4-20mA (load<750 Ω);
Output current error:
≤±1%FS;
relay:
AC220V、3A;
Communication interface:
RS485 optional;
Power Supply:
AC220V±22V ,50Hz±1Hz;
Protection level:
IP65;
Clock accuracy:
± 1分/月;
Data storage:
1 month (1 hour/5 minutes);
Overall dimensions:
146 (length) x 146 (width) x 108 (depth) mm;
Opening size:
138×138 mm
Weight:
0.8kg;
Working conditions:
Environmental temperature 0-60 ℃, relative humidity<85%;
Can be equipped with four types of conductive electrodes: 0.01, 0.1, 1.0, and 10.0.
Display mode: LED (digital tube) display, high brightness, eye-catching and intuitive, with a long visible distance
Measurement range: electrode constant × (1-3000) μ S/cm, 0-99.9 ℃
0.01~30μS/cm ; (with 0.01 electrode);
0.1~300μS/cm ; (with 0.1 electrode);
1.0~3000μS/cm ; (Equipped with 1.0 electrode);
10-30000 μ S/cm (with 10.0 electrode);
Resolution: 0.001 μ S/cm, 0.1 ℃
Electrode constant: set by software between 0.001 and 15.0 cm-1
Temperature compensation range: automatic 0-99.9 ℃, manual 0-99.9 ℃, converted to 25 ℃
Accuracy: ± 0.5% FS, ± 0.3 ℃
Current isolation output: 4-20 mA (load<750 Ω).
Alarm relay: AC220V, 3A, alarm signal isolated output
Communication interface: isolated RS485
Power supply: AC220V ± 22V, 50Hz ± 1Hz
Protection level: IP65
Working conditions: ambient temperature 0-60 ℃, relative humidity ≤ 90 ℅
Power off storage:>10 years
Weight and size: 0.8kg, 146 × 146 × 108 mm
Hole size: 138x138mm;
Secondary meter installation methods: perforated/wall mounted/rack mounted/pipe mounted
Electrode installation methods: flow-through/submerged/flange/pipeline
Standard configuration: one secondary meter, one set of measuring cells, and one electrode