What are the reasons why the head of the sewage self-priming pump in use cannot be reached?
Sewage self-priming pumpThere are several reasons why the head cannot be reached:
1. The suction pipe of the sewage self-priming pump is equipped with a bottom valve at the suction port, but the bottom valve cannot lift normally. It is recommended to choose a suitable bottom valve.
2. Due to the length of the inlet pipeline exceeding the self-priming capacity of the sewage self-priming pump, if the pipeline submerged in water is more than 1 meter, it is recommended to shorten the length of the pipeline in the water to reduce the self-priming distance.
3. The sewage self-priming pump has not yet sucked up the water, so the end of the outlet pipeline has not discharged water. Some users understand this situation as the reason why the head of the sewage self-priming pump cannot be reached. Therefore, a ball valve and pressure gauge should be installed at the outlet of the sewage self-priming pump, and the pressure gauge should be installed between the pump outlet and the ball valve to facilitate observation of the outlet pressure and determine whether water has been sucked up.
4. The selection of the sewage self-priming pump is incorrect. The actual working condition head is too high, and the head of the sewage self-priming pump cannot meet the actual working condition requirements. The solution to this problem is to replace the high head sewage self-priming pump.
5Sewage self-priming pumpThe transported liquid contains impurities and particles. Due to blockage in the pipeline or pump body, the head of the sewage self-priming pump cannot be reached. It is recommended to use a self-priming sewage pump for transporting sewage.
6. The liquid being transported is highly corrosive, and the impeller of the sewage self-priming pump has suffered severe corrosion. It is recommended to choose corrosion-resistant sewage self-priming pump products such as stainless steel sewage self-priming pumps or fluoroplastic sewage self-priming pumps. Alternatively, after prolonged use, the impeller of the sewage self-priming pump may experience wear and tear. The large gap between the impeller and the pump cover is also a reason why the head of the sewage self-priming pump cannot be achieved. It is recommended to replace the impeller with a new one.
7. Purchased by the userSewage self-priming pumpThere is a mistake between the head and the self equipped motor, for example: the actual motor required is 2900r/min, but the user has configured a motor with 1450r/min.