-
E-mail
dawei.zhao@aichrom.com
-
Phone
15210979260
-
Address
No.1 Zhongguancun North Second Street, Haidian District, Beijing
Ningbo Aichun Biotechnology Co., Ltd
dawei.zhao@aichrom.com
15210979260
No.1 Zhongguancun North Second Street, Haidian District, Beijing
Protein Purification SystemIt is a scientific instrument used for separating and preparing biomolecules such as proteins, nucleic acids, peptides, etc. It is widely used in fields such as chemistry, biology, biopharmaceuticals, food industry, agriculture, and environmental science.
Advantage:
Modular design: support the combined application of multiple chromatography technologies, such as gel filtration, ion exchange, affinity chromatography, etc., to meet complex separation requirements.
High precision and sensitivity: The detector has high resolution and can detect microgram level proteins, ensuring the accuracy of purification results.
High degree of automation: from sample loading, chromatographic separation to sample collection, the entire process is automated, reducing human error and improving experimental efficiency.
Strong compatibility: Supports multiple buffer solutions and mobile phases to meet the purification needs of different proteins.
Data traceability: Control software automatically records experimental data for subsequent analysis and reproduction.
Protein Purification SystemHigh precision, precise components, standardized maintenance can extend service life and ensure experimental stability. The maintenance items are as follows:
Flow path cleaning: used weekly5%-10%Rinse the flow path with ethanol or sodium hydroxide solution to remove residual proteins and microorganisms, and prevent pipeline blockage.
Detector maintenance: Regularly wipe the flow cell of the UV detector. If the detection sensitivity decreases, replace the light source or flow cell;pH/The conductivity detector needs to be calibrated regularly.
Pump body maintenance: Check the pump head gasket and replace it promptly if there is any leakage; When not in use for a long time, rinse the pump body with deionized water to prevent salt crystallization from damaging the components.