'Precise Catcher' DustVue 10- Directly hitting photovoltaic modules to reduce dust pollution losses
Date: 2025-12-23Read: 18
“精准捕手”DustVue 10-直击光伏组件降尘污染损失
“精准捕手”DustVue 10-直击光伏组件降尘污染损失

Photovoltaic module dust reduction pollution loss

monitoring sensor

“精准捕手”DustVue 10-直击光伏组件降尘污染损失
“精准捕手”DustVue 10-直击光伏组件降尘污染损失
“精准捕手”DustVue 10-直击光伏组件降尘污染损失
“精准捕手”DustVue 10-直击光伏组件降尘污染损失

DustVue 10


Dust pollution caused by photovoltaic modules can lead to a 10% -20% decrease in power generation, while traditional monitoring is difficult to accurately quantify losses. Our recent releasesPhotovoltaic module dust reduction pollution loss monitoring sensor DustVue 10We have adopted the (most) reliableDouble board comparison methodIntegrate all measuring devices into a compact and easy to install sensor, achieving low maintenance and easy operation.




“精准捕手”DustVue 10-直击光伏组件降尘污染损失





Eight core advantages



high-precision measurement


The uncertainty is only ± 1%



Double sided monitoring


Synchronize capture of pollution losses on both sides of the component

(Extremely) high cost-effectiveness



Low maintenance design


6 months or even longer

Perform a simple maintenance



sturdy and durable


Industrial grade surge protection

Reliable operation in harsh environments



Compliant with IEC61724-1 standard


Using the short-circuit current method



Easy to install


Small body and light weight

Quickly configure web server



consistency


Achieved (optimal) spectral matching with mass-produced components



Convenient integration


Supports RS-485 Modbus RTU protocol

Easy integration with existing systems



Reliable measurement principle


The calculation is based on short-circuit current and temperature of photovoltaic cells, in accordance with IEC standards, to minimize the spectral response difference between the photovoltaic module and the actual operation.



Unique features, double-sided monitoring


DustVue 10 can simultaneously measure the dust pollution loss on both sides of photovoltaic modules, making it an ideal choice for double-sided photovoltaic modules due to its high cost-effectiveness.



Easy to install and maintain


Installation can be completed within a few minutes, and can be installed on the same bracket as the running photovoltaic modules or on the weather station.

It is expected to undergo maintenance every six months (or longer), significantly reducing operating costs.